My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1777
>
2300 - Underground Storage Tank Program
>
PR0232397
>
COMPLIANCE INFO_2009-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 1:49:50 PM
Creation date
6/3/2020 9:56:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2013
RECORD_ID
PR0232397
PE
2361
FACILITY_ID
FA0003978
FACILITY_NAME
KAISER FOUNDATION - MANTECA
STREET_NUMBER
1777
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
20018034
CURRENT_STATUS
01
SITE_LOCATION
1777 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1777\PR0232397\PERMANENT INJUNCTION 05-11-11.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
k <br />LVIT1*1 •I V-24j'!•I I I I 1 5 1 P -Mr. I I I Zia I•I I I a I I I j-0awlev!b. <br />m <br />*n March 13, 2006, Ms. Le spoke with Mr. Brakkee and informed him that their <br />gecondary containment testing was due by December 2005 and was past due. Mr. <br />Brakkee stated he would schedule the tests. <br />On April 7, 2006, secondary containment testing was performed and a test report was <br />zubmitted to the EHD (Attachment 6). All components passed. <br />On August 30, 2006, Mr. Muniappa Naidu, Senior REHS, EHD, performed a routine UST <br />inspection (Attachment 7) and witnessed the annual monitoring system certification and <br />spill container testing. Annual line tightness testing was not performed this day, but Mr. <br />Naidu indicated in the report that it would be due by November 2006. No violations were <br />noted and all components tested passed. A test report, due thirty days after testing, was <br />never submitted. <br />On August 30, 2007, Mr. Naidu performed a routine UST inspection (Attachment 8) and <br />witnessed the annual monitoring system certification and spill container testing <br />(Attachment 9). Annual line testing due by November 2006, was not done, though Mr. <br />Naidu did not indicate that on the inspection report. During a review of the facility's files, <br />Mr. Naidu found that a new designated operator had been hired but notification was not <br />provided to the EHD. <br />On August 28, 2008, Mr. Naidu performed a routine UST inspection and witnessed the <br />annual monitoring system certification and spill container testing. Mr. Naidu noticed tha) <br />there appeared to be newly poured concrete around the tank. Upon closer inspection, <br />two new pipes were found installed through the piping sump without any penetration <br />fittings. Mr. Brakkee stated he did not know about the work done on the LIST system. <br />Mr. Naidu included a Notice to Abate Immediately on the inspection report to stop work <br />on the UST system and to submit a permit application for approval (Attachment 11). A <br />test report, due thirty days after testing, was never submitted. <br />P11 <br />