My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1777
>
2300 - Underground Storage Tank Program
>
PR0232397
>
COMPLIANCE INFO_2009-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 1:49:50 PM
Creation date
6/3/2020 9:56:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2013
RECORD_ID
PR0232397
PE
2361
FACILITY_ID
FA0003978
FACILITY_NAME
KAISER FOUNDATION - MANTECA
STREET_NUMBER
1777
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
20018034
CURRENT_STATUS
01
SITE_LOCATION
1777 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1777\PR0232397\PERMANENT INJUNCTION 05-11-11.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, ~m <br /> COY <br /> San Joaquin County <br /> ooeoronEnv8ronmentU Health Department <br /> Donna Ho,an.nE*S <br /> 1868 East Hazelton Avenue <br /> PROGRAM COORDINATORS <br /> Stockton, California 95205-6232 <br /> Rnuertmoc|enon. ne*u <br /> ---�-----------'-------------'--'-------------- <br /> Jeff Conueouo. xeHa` RDI <br /> �asvypo/ovns*� <br /> Website: m/w/vuuy��um�P�h� unuaTu,xa'o �s*s <br /> -^-=-~ Phone: (209) 468-3420 Rodney Estrada,nsHS <br /> Fax: (209) 464-0138 Adrienne exap*su:r.neHs <br /> October Q` 2013 <br /> ` <br /> Wayne <br /> Gathh ht <br /> Cal Phase Constriction, Inc. <br /> 1775 Monterey Rd, Ste. GO-A. <br /> Gan Jooe, CA 95112 <br /> Re: Kaiser Hospital, 1777 VV Yosemite Ave, M8DteCo, CA SR0067724 <br /> The Gen Joaquin County Environmental Health Department /EH[) has reviewed the permit <br /> application to nannova the underground piping tee of the generator/boiler F.O.F| line, remove/or <br /> abandon in place return piping associated with the above ground storage tank (AGT), repair the <br /> primary and the secondary piping where.the aforementioned tea was rennoVad, modify piping at <br /> . the sump on the underground storage t8Mh (UST) oyoteUl, and connect all the sensors to the <br /> existing TLS 350 Plus VeSd8r Root nO0DitO[iDQ panel and recertify the system at the above <br /> referenced address. <br /> In order for this permit application review to omntinue, an addendum and revised sheets for the <br /> plans must besubmitted for the ho||ovvinQ deficiencies: <br /> 1. Sheet number F0-(31. Cover Sheet, Site Plan, Notes & &8apS. states "the pipe that <br /> ,cannot be removed shall be triple rinsed and abandon[ed] /n place per the /4HJ <br /> Instructions"' Since some piping may be abandoned in place, a Closure in Place permit <br /> needs to be submitted prior to mobilization on mita. A copy of permit application is <br /> attached to this letter. Applicant shall also submit a written approval from the City or <br /> County Fire Prevention Bureau with jurisdiction allowing the Closure in Place (C|p) prior <br /> to the EHO permit approval. <br /> 2. Sheet number F0-G1. Cover Sheet, Site Plan. Notes & Maps, states "Remove the tee <br /> and as much of the 8GSOCiah9d pipe, that /s associated with the generator day tank <br /> overflow, 88 possible." It is EH[)'s understanding that the proposed underground piping <br /> modification is to disconnect the return line leading from the boiler and not the one <br /> leading from the generator. Please provide clarification, and revise the above quoted <br /> statement to reflect the proposed scope of vv0rh, as appropriate, and submit a revised <br /> sheet number F[)-G1 forEHD'o review and approval. <br /> 3. Sheet Dumber F0-M1.3, Modified Above Ground Fueling Piping Plan (F.O.S/F.O.R <br /> ConnecU0D), illustrates two supply lines ((F) F.0.C. from (F) L/Q7l without @ return line <br /> to the UST. Submit a revised sheet number FO-K81 with the required information. <br />
The URL can be used to link to this page
Your browser does not support the video tag.