Laserfiche WebLink
REMOVE PUMP& MOTORS <br /> MOTORS PETRO <br /> REMOVE (E)PIPING ASSOCIATED -ANALYTICAL, INC. <br /> 2) PO. BOX 2301, ORINDA, CALIFORNIA 94563 <br /> REMOVE <br /> WITH PUMPS. (E)CONCRETE FOUNDATION T. (925) 253-0591 FAX (925) 927-823-2427 <br /> WALL <br /> ALL DRAWINGS AND SPECIFICATIONS AND THE CONCEPTS <br /> P <br /> 4 EMBODIED WITHIN THESE DRAWINGS ARE THE ORIGINAL <br /> a (E)BLACK STEEL VENT <br /> .a ° ° PIPING UNPUBLISHED WORKS OF PETRO ANALYTICAL,INC. NO PART OF <br /> THESE MATERIALS MAY BE UTILIZED,REFERENCES, DISCLOSED OR <br /> (N)AMERON BLACK STEEL PIPE REPRODUCED, IN ANY AND ALL MANNER OR BY ANY AND ALL <br /> 4 .,4 -- COUPLING MEANS, FOR DESIGN,CONSTRUCTION OR RELATED PURPOSES, OR <br /> 4 _ q . <br /> ." <br /> 44 e ANY OTHER PURPOSES ON OTHER PROJECTS OR EXTENSION OF <br /> 4 THIS PROJECT.ANY USE OF THE PROJECT DOCUMENTS REQUIRES <br /> d ° (N)AMERON LCX BELL X MALE <br /> WRITTEN CONSENT OF PETRO ANALYTICAL,INC.. <br /> 4 . °. 4 ADAPTER <br /> 4 A ° USE P5000 STRUT OR AS <br /> .. REQUIRED TO SUIT FIELD <br /> ra ° e CONDITIONS <br /> LOY <br /> C � 4 a (N)AMERON LCX TEST FITTING <br /> a <br /> V <br /> (N)CONCRETE PATCH-SEE <br /> 4 . 9 a BIFO-M2 <br /> 4 . 4 4. • 4 b da <br /> A <br /> �d�FitF�• V'�-� 2 11 ,� ,y 4 d, <br /> 4 2112SCH.40S'FEELPIPE REV.NO DESCRIPTION DATE <br /> a <br /> SLEEVE. PROVIDE CAULKING <br /> REMOVE(E)F.G.,F.O.S.&F.O.R. EE NOTE 3 BELOW. 4 '° e .d Q- SUBMITTAL 4-9-13 <br /> PIPING AND SUMP PENERATION <br /> FITTINGS <br /> a <br /> 4 � 0 COUNTY REVS. 10-10-13 <br /> REPLACE (E)SENSOR WITH(N) 4 c 4 4 DOUBLE WA(N)AMERONLL VENT PIPING UALOY 3000 CX BAGKCHECK #1 10-15-13 <br /> VEEOER-ROOT SENSOR n (N)AMERON DUALOY OWNER REVISIONS 4-4-14 <br /> 3000 LCX ELBOW <br /> 10 SUMP PIPING DEMOLITION 9 PARE SCALE: NONE <br /> PLAN AND NOTES SCALE: NONE 4 SPARE SCALE: NONE <br /> -- NOTE: <br /> PAINT ALL ABOVE GROUND <br /> 2 FIBELIGLASS PIPE WITH A OOD <br /> QUALITY WHITE LATEX EXT <br /> ERIOR <br /> (E)SINGLE WALL STEEL PAINT OSHPD # S131392-39-00 <br /> 3 <br /> VENT LINE(VERIFY OSHPD APPROVAL: <br /> 3 <br /> TESTABLE VENT TRANSITION FRO <br /> OMEGA-FLEX F.O.R. PIPING -------- <br /> -- LCX PIPE TO STEEL PIPE SCALE: 3"=l'-0" <br /> WITHIN A 4"CHASE _ <br /> ��� (N)TLM-SEE NOTE <br /> FBREEZE#44 9/6"STEEL BAND <br /> / `I— I-� ♦ CLAMP Q 48"00. <br /> EXISTING LOUVER PANEL <br /> BETWEEN LOUVERS, <br /> ❑ • \\( EP <br /> OMEGA-FLEX PIPING PER (E) <br /> / I MANUFACTURER'S MIN, BEND RACK <br /> I RADIUS REQUIREMENTS <br /> OMEGA-FLEX F.O.S. I I-I - I- PROJECT ENGINEER: CONSULTANT: <br /> PIPING WITHIN A <br /> 4"CHASE \\ • _I— —I- 1 CONTINUOUS P1000 SUPPORTING <br /> O O i i FLEXIBLE PIPING <br /> SECURE WW BOLT 8 <br /> \ • e I—I I I I / LOCK-NUT TO (E) BOOT <br /> REALIGN AND <br /> BRACKET <br /> RECONNECT <br /> (N)SENSOR AND J-BOX <br /> 3 <br /> a OP\yOGESSIONA< <br /> AFTER PIPING "PVC CHASE (ELECT.CONDUIT), < y0 ON M. NFy, 6y <br /> I . I—' / PAINT TO MATCH BUILDING ti? <br /> ? <br /> MODIFICATIO // <br /> (E)WALL MOUNTED OMEGA-FLEX VOR 1 1/2" <br /> EXTRACTOR FITTING --- EXTRACTOR FITTING Na022W a <br /> Z ^` <br /> PIPE BRACKETS TO 'L .M6 �* <br /> 4"X 2"-SEE NOTE 1 4"X 2" BE REUSED(REMOVE FUEL PIPING ExV.au36n5 <br /> PLAN $ SPARE SCALE: NONE r <br /> BELOW (E)PIPING) I bF0 P�' <br /> OF HF <br /> RE-USE CONDUIT FOR <br /> USE NDEDICATED <br /> APR 9 2014 <br /> CONNECTION TO a <br /> VEEDER-ROOT PANEL /2 4 <` PROJECT TITLE: <br /> l�, P1119 PIPE CLAMP,TYP.4 a '.d <br /> ° MODIFICATION OF EMERGENCY <br /> 5 SPARE SCALE: NONE POWER FUEL SYSTEM <br /> FOUNDATION <br /> ALLWITOCONC. KAISER PERMANENTE <br /> FOUNDATION WALL WITH HILTI LL <br /> o e 4 u <br /> KB-TZ-SS 3/8"EXPANSION <br /> (E)5"CONCRETE ANCHORS,17DO2 PER NOT <br /> EXIST M MANTECA HOSPITAL <br /> SLAB 4 H DO NOT DAMAGE EXISTING <br /> 4 " REINFORCING <br /> (E) REALIGNED LEAK Q <br /> TORQUE TEST=25 FT-LBS 1777 W. YOSEMITE AVENUE <br /> SENSOR AND J-BOX 2 FO 6"CONCRETE <br /> FOUNDATION WALL 4YARD SLAB PATCH, M A A <br /> . a � 4 : <br /> /'1ITEM A <br /> SEE 6/FO-M2 1 V 4/"1, CA 95333 <br /> SEE NOTE 3 <br /> #4 SMOOTH DOWELS,GRADE 60® <br /> SAWCur 12"O.0 @SLAB CENTERLINE, 4 0 ° PROJECT NUMBER: 13003 <br /> LINE EPDXY INTO(E)SLAB W/HILT[ (E)CONC. FTG. <br /> EPDXY SYSTEM HIT-RE500-SD, <br /> PULL TEST NOT REQUIRED,TYR d DRAWN BY: JRS <br /> ALL SIDES OF INFILL <br /> I _ — TO(E)UST <br /> ------ -- -- - - ------ . d <br /> 4:, 4. : CHECKED BY: AMN <br /> O '. , .4 � LAP ; <br /> ll <br /> SCALE: ASSHOWN d W j a NOTE: <br /> d ° �_+: a (E)FOUNDATION INFORMATION <br /> (N) SUPPLY EXTRACTOR I 1_ ��— FROM RECORD BUILD DRAWINGS, <br /> tt--..pp �-p m `� SHEET TITLE <br /> IIS (N) RETURN EXTRACTOR v�o� °� AoV �� oO�.p� ° $ m ST DOMINICS HOSPITAL"BY <br /> FITTING 4"X 2" FITTING 4"X 2" °o •o Qa ^o ° a e BUTZBACK/13AR-DIN 8 DAIGEN 1988 <br /> NOTE: <br /> SEE NOTE 2 EXTEND DOWELS FROM EACH 4 ° 4. 4 <br /> SIDE OF PATCH AS REQUIRED <br /> SEE NOTEI SECTION EMBED 7 FOR 4"OVERLAP, TYP.AROUND 4 �. 4 G 4 4 <br /> (E) VENT TEE WITH <br /> PEA GRAVEL BACKFILL 4 MISC. DETAILS <br /> GAUGING CAP E INFILL 2500 <br /> PIPING SUMP NOTES: PATCH INFILL I CONCRETE <br /> 1. INSPECT THE STINGER PREVIOUSLY USED FOR THE SUCTION FOR THE <br /> FILL <br /> SUPPLY SUMPS. INSTALL A NEW DOUBLE POPPET VALVE <br /> APPROXIMATELY 4" FROM THE BOTTOM OF THE TANK.AN EXTRACTOR SECTION <br /> FITTING WILL BE USED TO INSTALL THE FOOT VALVE <br /> 2. INSTALL(N)TLM IN AVAILABLE PENETRATION. SHEET NUMBER <br /> 3. PROVIDE DEDICATED CONDUIT FOR SIGNAL TO VEEDER-ROOT PANEL. <br /> (ONE OF THE CONDUIT THAT PREVIOUSLY SUPPLIED POWER TO THE <br /> PUMPS MAY BE USED). <br /> 11 PIPING MODIFICATIONS @ SCALE: NONE 7 SPARE SCALE: NONE 6 CONCRETE PATCH INFILL SCALE: 3"=r-o' 1 OMEGA-FLEX PIPE SUPPORT scALE: 3"=r-o° FO=M2(E) TANK SUMP @ YARD SLAB <br />