Laserfiche WebLink
DEDUCTIONS <br />6 <br />7 <br />BOX FILL TABLE <br />8 9 <br />10 <br />11 <br />12 <br />13 <br />14 <br />as well as clamps, fittings, or devices <br />#18 (1.50) <br />9.00 <br />10.50 <br />12.00 <br />13.50 <br />15.00 <br />16.50 <br />18.00 <br />19.50 <br />21.00 <br />Volume <br />#16 (1.75) <br />10.50 <br />12.25 <br />14.00 <br />15.75 <br />17.50 <br />19.25 <br />21.00 <br />22.75 <br />24.50 <br />Required per <br />#14 (2.00) <br />12.00 <br />14.00 <br />16.00 <br />18.00 <br />20.00 <br />22.00 <br />24.00 <br />26.00 <br />28.00 <br />Conductor <br />#12 (2.25) <br />13.50 <br />15.75 <br />18.00 <br />20.25 <br />22.50 <br />24.75 <br />27.00 <br />29.25 <br />31.50 <br />Size per <br />#10 (2.50) <br />15.00 <br />17.50 <br />20.00 <br />22.50 <br />25.00 <br />27.50 <br />30.00 <br />32.50 <br />35.00 <br />Deductions <br />#8 (3.00) <br />18.00 <br />21.00 <br />24.00 <br />27.00 <br />30.00 <br />33.00 <br />36.00 <br />39.00 <br />42.00 <br />#6 (5.00) <br />30.00 <br />35.00 <br />40.00 <br />45.00 <br />50.00 <br />55.00 <br />60.00 <br />65.00 <br />70.00 <br />Calculate The Minimum Size Box <br />Points to Remember: <br />Example - Bell® Weatherproof <br />Part (1) of Section 370-16(a) describes <br />1. No matter how many ground wires <br />Supply power to a single switch with <br />in detail the method of counting wires, <br />come into a box, they only count as <br />#14 conductors. Metal conduit will be <br />as well as clamps, fittings, or devices <br />one conductor within the box. <br />used as the wire way. You must provide <br />(i.e., switches, receptacles, combination <br />space for four conductors and one <br />devices) - by establishing an equivalent <br />2. Any wire running unbroken through the <br />switch, totaling 6. Read across the line <br />conductor -value for each. These values <br />box counts as one wire. <br />"Deductions" in the Box Fill Table to <br />are added together to get a total number <br />3. Each wire coming into a splice device <br />column 6, then read down to the mini - <br />of conductors. The minimum size box is <br />(crimp or twist -on type) is counted as <br />mum cubic inches required for #14 con - <br />the smallest one in the Box Fill Table <br />one wire. <br />ductor. This example requires a minimum <br />(shown) that can accommodate that <br />of 12.0 cubic inches. <br />number of conductors. <br />4. Each wire coming into the box and <br />connecting to a device counts as one <br />wire of that size. <br />5. Where devices are mounted in the <br />box, the total conductor count must <br />C <br />be increased by two for each <br />P1, E <br />mounting strap. <br />FEB0 62011 <br />LT <br />E:NTAS <br />int <br />DEPARTMENT <br />183 <br />