My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1989-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MICHAEL CANLIS
>
7000
>
2300 - Underground Storage Tank Program
>
PR0232437
>
COMPLIANCE INFO_1989-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 12:52:20 AM
Creation date
6/3/2020 9:57:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1989-2008
RECORD_ID
PR0232437
PE
2361
FACILITY_ID
FA0003787
FACILITY_NAME
SHERIFFS OPERATIONS CTR #1
STREET_NUMBER
7000
Direction
N
STREET_NAME
MICHAEL CANLIS
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19305014
CURRENT_STATUS
01
SITE_LOCATION
7000 N MICHAEL CANLIS RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232437_7000 N MICHAEL CANLIS_1989-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
427
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB. January 2002 Page 5 of 7 <br />7. R -DISPENSER CONTAINMENT C) TESTING <br />Test Method Developed By: <br />[ <br />] UDC Manufacturer [ ] Industry Standard [ ] Professional Engineer <br />[ <br />] Other (Specify) <br />Test Method Used: <br />[ <br />] Pressure <br />[ <br />] Vacuum <br />[ ] Hydrostatic <br />[ <br />] Other (Specify) <br />Test Equipment Used: <br />Equipment <br />Resolution: <br />._.. �.. <br />UDC # <br />UDC # <br />UDC # <br />UDC Manufacturer: <br />UDC Material: <br />UDC Depth: <br />Height from UDC <br />Bottom to Top of <br />Highest Piping <br />Penetration: <br />Height from UDC <br />Bottom to Lowest <br />Electrical Penetration: <br />Condition of UDC <br />prior to testing: <br />Portion of UDC <br />Tested 1 <br />Does turbine shut down <br />[ ] YES [ ] NO <br />[ ] YES [ ] NO <br />[ ] YES [ ] NO [ ] NA <br />when UDC sensor <br />[ ] NA <br />[ ] NA <br />detects liquid (both <br />product & water)? <br />Turbine shutdown <br />response time: <br />Is system programmed <br />[ ] YES [ <br />] NO <br />[ ] YES[ <br />] NO <br />[ ] YES [ ] NO <br />for fail-safe shutdown? <br />[ ] NA <br />NA <br />[ NA <br />Was fail-safe verified <br />[ ] YES [ <br />] NO <br />[ ] YES [ <br />] NO <br />[ ] YES [ ] NO <br />to be operational? <br />[ ] NA <br />[ ] NA <br />[ ] NA <br />Wait time between applying <br />pressure/vacuum/water & <br />starting test <br />Test Start Time: <br />Initial Reading (R1): <br />Test End Time: <br />Final Reading <br />Test Duration: <br />Change in Reading (Rf- <br />RI) <br />Pass/Fail Threshold or <br />Criteria: <br />Test Result,'' <br />PASS <br />I FAIL <br />I I PASS <br />I I 1FAIL <br />PASS I I FAIL <br />Was sensor removed for <br />[ ] YES [ <br />] NO <br />[ ] YES <br />[ ] NO <br />[ ] YES [ ] NO <br />testing? <br />[ ] N/A <br />] N/A <br />Was sensor properly <br />[ ] YES [ <br />] NO <br />[ ] YES <br />[ ] NO <br />[ ] YES [ ] NO <br />replaced and verified <br />[ ] N/A <br />[ ] N/A <br />[ ] N/A <br />functional after test? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />I If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an asterisk (*) is "NO" or <br />"NA", the entire sump must be tested. (SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.