My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MICHAEL CANLIS
>
7000
>
2300 - Underground Storage Tank Program
>
PR0232437
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2023 1:25:56 PM
Creation date
6/3/2020 9:57:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0232437
PE
2361
FACILITY_ID
FA0003787
FACILITY_NAME
SHERIFFS OPERATIONS CTR #1
STREET_NUMBER
7000
Direction
N
STREET_NAME
MICHAEL CANLIS
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19305014
CURRENT_STATUS
01
SITE_LOCATION
7000 N MICHAEL CANLIS RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232437_7000 N MICHAEL CANLIS_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
470
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Nov 12 09 04:56p 20 -367-5424 p.5 <br /> SAIRCB,January 2002 Page 1 <br /> L of 7- <br /> 6. PIPINGS TESTING <br /> Test Method Developed By: 0 Surnp Manufacturer 0 Industry Standard 0 Professional Engineer <br /> D Other(Specify) L <br /> Test Method Used: 0 Pressure 0 Vacuum 0 H;d static <br /> 0 Other(Specify) <br /> Test Equipment Used: Equipment R96lution: <br /> SUMP N SUMP# SUMP# SUMP <br /> Sump Diameter: <br /> Sumpi� <br /> Sump Depth: 7777 <br /> Sump Material: <br /> Height from Tank Top to Top of <br /> Highest Pipirig Penetration: <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: <br /> Condition of sump prior to testing:] <br /> Portion of Sump Tested' <br /> Does turbine shut down when <br /> sump sensor detects liquid(both :3 Yes D No NA 0 Yes CW/O DNA OYes ONo [INA OYes, -,::]No -INA <br /> product and water)?* <br /> Turbine shutdown,response time <br /> Is system programmed for fail-safe Yes <br /> shutdown?* 0 No 0 N:4 0 No 0 NA 0 Yes 0 No 0 NA 0 Yes D No DNA <br /> Was fail-safe verified to be Yes ONo ON Yes DNo, DNA OYes ONo DNA OYes ONo 3 N <br /> operational?* <br /> Wait time between applying <br /> pressureNacuum/water and starting <br /> test: <br /> Test Start Time: <br /> Initial Reading(R,): <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: <br /> Change in Reading(RF-Rj): <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: 1 /D Pass 0 Fall 0 -Pass 0 Fail 0 Pass t Fall 0 Pass 0 Fail <br /> Was sensor removed for testing? TOYes C-No [INA OYes ONo L---NA 0 Yes 0 No 0 NA E Yes 0 No 0 NA <br /> Was sensor properly replaced and <br /> OYes 0No DNA OYes ONo DNA DYes ONo DNA E:Yes DNo ED!NAj <br /> verified functional after test _ <br /> Comments—(include information on repairs made prior to testing and recommendedfoMTt±efor failed tests) <br /> If the entire depth of the sump is not tested, specify how much was tested. If the answer to my of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-I60) <br />
The URL can be used to link to this page
Your browser does not support the video tag.