FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
01
SITE_LOCATION
1960 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232534_1960 W ELEVENTH_1991-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
499
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DOUBLE CONTAINED PIPING <br />INTERSTITIAL SPACE MONITOR: X LIQUID <br />SUMP MONITOR: X LIQUID SENSOR Veeder-Root TLS -350 Single Float Series 794390-208 <br />EQUIPMENT AT THIS FACILITY IS: Veeder-Root TLS -350 PLLD Series 848480-001 <br />All double contained piping is continuously monitored electronically by a system that can sense a <br />leak at of 3 gallons or more per hour at 10 lbs. per square inch of line pressure within 1 hour at more <br />than one location with positive shut down. If the pressure sensor is activated, the line pressure <br />monitor is capable of sensing the pressure loss in the system and disables the flow of product <br />through the lines. All product lines are sloped down towards the tank, and any liquid in the annular <br />space will flow backwards into the sump area. There is a sensor in the sump area that detects any <br />liquid present there. The system has both visible and audible alarms that are activated when there is <br />liquid in the sump or detected in the secondary containment. At least annually, the system is <br />capable of detecting a release from the primary piping equivalent to .1 gph defined at 150% <br />operating pressure. <br />.a 1 <br />If the system goes into the alarm mode, the Operator or his designate will check the alarm panel to <br />verify that there is a leak condition and then silence the audible alarm. The Operator or his designee <br />will immediately contact Chevron dispatch and advise them of the situation so that they can contact <br />the appropriate personnel who will follow the instructions outlined in the "Leak Response Plan", <br />which is part of your Hazardous Material Management Plan. All follow up will be completed within <br />the month the problem occurred. <br />DISPENSER CONTAINMENT <br />SUMP MONITOR: X LIQUID SENSOR Veeder-Root TLS -350 Single Float Series 794390-208 <br />All dispensers are double contained with fiberglass pans that are continuously monitored <br />electronically using liquid sensors. The system has both visible and audible alarms that are activated <br />when liquid is detected. <br />The monitoring system will be inspected daily. The Operator or an employee appointed by the <br />Operator will follow the same procedures as outlined for monitoring the double contained product <br />tanks. <br />PREVENTATIVE MAINTENANCE <br />The monitoring equipment shall be inspected and certified annually. Maintenance will be performed <br />annually or as needed. All work performed to the monitoring system will be in accordance to the <br />manufacturers recommendations. <br />TRAINING <br />Tank operators are trained on the proper operations of the monitoring equipment per the <br />manufacturer's instructions. <br />Chevron Emergency Information Center (CEIC) 1-800-231-0623 <br />Chevron Maintenance Dispatch 1-800-423-3528 <br />