Laserfiche WebLink
0 RECEIVED <br /> AUG' 0 12016 <br /> 7. UNDER-DISPENSER CONTAINMENT(UDC)TESTINOVIRONy <br /> Test Method Developed By: ❑UDC Manufacturer ®Industry Standard ❑Profess iia CES <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum El Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: See attached testing procedures Equipment Resolution: Inches <br /> UDC# 1/2 UDC# 3/4 UDC# 5/6 UDC# 7/8 <br /> UDC Manufacturer: <br /> UDC Material: Fiberglass Fiberglass Fiberglass Fiberglass <br /> UDC Depth: 36" 36" 36" 36" <br /> Height from UDC Bottom to Top 14" 14" 14" 14" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to N/A N/A N/A N/A <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> Fair Fair Fair Fair <br /> testing: <br /> Portion of UDC Tested Above highest penetration Above highest penetration Above highest penetration Above highest penetration <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both N/A N/A N/A N/A <br /> product and water)'?* <br /> Turbine shutdown response time <br /> Is system programmed for fail- ❑Yes ❑No Q NA ❑Yes ❑No ®NA ❑Yes ❑No p NA ❑Yes ❑No p NA <br /> safe shutdown?* <br /> Was fail-safe verified to be ❑Yes ❑No O NA ❑Yes ❑No p NA ❑Yes ❑No ❑NA ❑Yes ❑No p NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 15 minutes 15 minutes 15 minutes 15 minutes <br /> startin test <br /> Test Start Time: 10:14am 10:14am 9:48am 10:14am <br /> Initial Reading(Rt): 2.70622 Inches 5.01828 Inches 0.57513 Inches 4.20891 Inches <br /> Test End Time: 10:29am 10:29am 10:03am 10:29am <br /> Final Reading(RF): 2.70646 Inches 5.01889 Inches 0.57631 Inches 4.20950 Inches <br /> Test Duration: 15 mins 15 mins 15 mins 15 mins <br /> Change in Reading(RF-RI): 0.00024 0.00061 0.00118 0.00059 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result: p Pass ❑Fail R1 Pass ❑Fail p Pass ❑Fail ® Pass ❑Fail <br /> Was sensor removed for testing? ❑Yes ❑No ❑NA ®Yes ❑No ❑NAp Yes E]No [-]NA [Z]Yes E]No El NA <br /> Was sensor properly replaced and ®Yes ❑No El NA p Yes ❑No ❑NA ®Yes ❑No ❑NA 0 Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testin)z, and recommended follow-up for failed tests) <br /> Dispenser Upgrade project conducted at this site under the San Joaquin County <br /> Environmental Health Permit SR0073163. <br />