My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2001-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1103
>
2300 - Underground Storage Tank Program
>
PR0232587
>
COMPLIANCE INFO_2001-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 11:22:36 AM
Creation date
6/3/2020 9:58:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2007
RECORD_ID
PR0232587
PE
2361
FACILITY_ID
FA0004521
FACILITY_NAME
CHEVRON USA #201761*
STREET_NUMBER
1103
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
21935038
CURRENT_STATUS
01
SITE_LOCATION
1103 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232587_1103 S MAIN_2001-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
371
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 2 <br /> 0 4. TANK ANNULAR TESTING 10 <br /> Test Method Developed By: F-1 Tank Manufacturer ❑X Industry Standard F-1 Professional Engineer <br /> Other (Sped) <br /> Test Method Used: FI Pressure FRI Vacuum Hydrostatic <br /> Other (Specify) <br /> Test Equipment Used: Equipment Resolution: <br /> Tank# 1 REG Tank# 2 PLU Tank# 3 SUP Tank# <br /> Is Tank Exempt From Testing?1 Ll Yes 1^1 No Yes X No YesX No Yes No <br /> Tank Capacity: 12000 12000 12000 <br /> Tank Material: DW FIBERG DW FIBERG DW FIBERG <br /> Tank Manufacturer: UNKNOWN UNKNOWN UNKNOWN <br /> Product Stored: REGULAR PLUS SUPREME <br /> Wait time between applying <br /> pressure/vacuum/water and 5 MIN 5 MIN 5 MIN <br /> starting test: <br /> Test Start Time: 8:35 8:27 8:23 <br /> Initial Reading(RI): 10 HG 10 HG 10 HG <br /> Test End Time: 9:35 9:27 9:23 <br /> Final Reading(RF ): 10 HG 9 HG 9 HG <br /> Test Duration: 1 HR 1 HR 1 HR <br /> Change in Reading(RF-11 ): 0 1 1 <br /> Pass/Fail Threshold or Criteria: 2 2 2 <br /> Was sensor removed for testing? Yes X X N NA Yes N NA Yes R N NA Yes N NA <br /> Was sensor properly replaced and ❑Ye XN�NAYe�NNA YesMN e ] <br /> N NA <br /> verified functional after testing? ❑ <br /> Comments- (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. (California Code of Regulations,Title 23,Section 2637(a)(6)) <br />