My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2001-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1103
>
2300 - Underground Storage Tank Program
>
PR0232587
>
COMPLIANCE INFO_2001-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 11:22:36 AM
Creation date
6/3/2020 9:58:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2007
RECORD_ID
PR0232587
PE
2361
FACILITY_ID
FA0004521
FACILITY_NAME
CHEVRON USA #201761*
STREET_NUMBER
1103
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
21935038
CURRENT_STATUS
01
SITE_LOCATION
1103 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232587_1103 S MAIN_2001-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
371
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
62/21/2003 14:58 FAX 9258425660 CHEVRON PRODUCTS COMPANY - CB 0 001 <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> PgU�N SAN JOAQUIN COUNTY <br /> A .. Donna K.Heran,R.E.H.S. Unit Supervisors <br /> a„•4,.: <br /> + Carl Bor an,R.E.H.S. <br /> 304 East Weber Avenue, Third Floor <br /> Director Mike Huggins,R.E.H.S.,R.D.I. <br /> Al Olsen,REM.s Stockton, California 95202-2708 <br /> • x:• P• <br /> Q�iFOR�� Douglas W.Wilson,R.E.H.S <br /> .Pro am Manager -3420 <br /> Laurie A.Cotulla,R.E:H.S. Telephone: (209)468 Margaret Lagorio,RE.H.S. <br /> Robert McCleilon,R.E.H.S. <br /> February 20,2003 Program Manager Fax: (209)464-0138 RMark McClBarcellos,R.E.H.S. <br /> CHEVRON USA#201761* <br /> PERMIT DESK <br /> PO BOX 6004 <br /> SAN RAMON CA 94583 <br /> Re: Secondary Containment Testing on the Underground Storage Tank System(UST)at i <br /> 1-103-S MAIN ST MANTECA 95337 - - - <br /> In accordance with, California Health & Safety Code 25291, every underground storage tank shall be designed and <br /> constructed to provide primary and secondary levels of containment of hazardous substances stored in it. In addition, <br /> California Code of Regulations 2636(a)states that,piping connected to tanks,which were installed after July 1, 1987,shall <br /> have secondary containment that complies with the requirements of section 2631 for new underground storage tanks. <br /> By January 1, 2003, underground storage tank owners and operators were required to have their secondary containment <br /> systems tested[California Code of Regulations(CCR)Section 2637(a)1. <br /> This notice is to inform you that San Joaquin County Environmental Health Department(EHD)received the above <br /> referenced facility secondary containment test results.It has been noted that a failure has occurred within your secondary <br /> containment system.In accordance with State Water Regional Control Board policy LG 160,EHD required repairs to be <br /> made within 120 days of the original test date.If this system was not repaired within 120 days from the original test date <br /> then an application to remove the underground storage tank component that failed should be submitted to this office <br /> within 30 days of the date of this letter.A statement explaining the scope of work for the secondary containment repair <br /> must be submitted to this department prior to beginning any repair.A permit from this office is required prior to <br /> commencing work/breaking concrete.Consult with EHD for advice on permit requirements. <br /> In addition,this office must be notified 48 hours in advance of performing the official retest of the secondary containment <br /> system. If notification is not made to this office prior to testing the results will not be accepted. Results from this testing <br /> must be received by this office within;30 days after performing the test. <br /> It should be noted that this facility's underground storage tank operating permit will not be issued or may be revoked to <br /> owners/operators who can not demonstrated that their secondary containment_systems are structurally.sound.And you shall <br /> not operate an underground storage tank system without a permit[Health'&Safety Code(HSC)Section 252841. <br /> As of this date,this office has not received one(or more)of the following: <br /> C Scope of work performed to repair secondary containment failure V zlllo / <br /> C Permit to repair ust system prior to retest t Z/t P/Z f <br /> C <br /> C Notification of secondary containment retest after repairs have been made L-t`} <br /> !7 Application to remove and replace the ust or component that could not be pass— --/1 <br /> RL-Tt�T SPNT 7,6 €11L> th(.1. z. <br /> If you have any questions regarding this matter please contact Doug Wilson, Supervising Registered Environmental Health <br /> Specialist at(209)468-3446. <br /> Thank you, <br /> Doug Wilson <br /> Supervising REHS <br />