My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2001-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1103
>
2300 - Underground Storage Tank Program
>
PR0232587
>
COMPLIANCE INFO_2001-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 11:22:36 AM
Creation date
6/3/2020 9:58:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2007
RECORD_ID
PR0232587
PE
2361
FACILITY_ID
FA0004521
FACILITY_NAME
CHEVRON USA #201761*
STREET_NUMBER
1103
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
21935038
CURRENT_STATUS
01
SITE_LOCATION
1103 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232587_1103 S MAIN_2001-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
371
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AUG 23 ' 01 8 :05 FROM G TTLER RYAN TO 842 60 PAGE . 003i004 <br /> Monitoring System Certification <br /> D. Results of Testing/Servicing <br /> Software Version Installed. AxJ <br /> Complete the following checklist: <br /> G1 Yes ❑ No* Is the audible alarm aperatioMl? <br /> ❑ Yes ❑ No* Is the visual alarm operational? <br /> E3 Yes ❑ No' Were all sensors visually inspected,functionally tea a,and operational? <br /> irsned <br /> ❑ Yes ❑ No Were all sensors installed at lowest point of$Cron tainment and positioned so that other equipment will <br /> not interfere with their proper operation —A er_� <br /> ❑ Yes ❑ No* If alarms are relayed to a remot mo station, is all communications equipment (e.g. modem) <br /> ❑ N/A operational? <br /> 0 Yes C3 No* For pressurized piping systems,does t turbine automatically shut down if the piping secondary containment <br /> ElN/A monitoring system detects a e .1f . to operate,or is electrically disconnected? If yes: which sensors initiate <br /> positive shat-down? (Choc at apply) ❑ Sump/Trench Sensors; 0 Dispenser Containment Sensors. <br /> Did you conf rn.positi a own due to leaks and sensor failure/disconnection? ❑Yes; ❑No. <br /> p Yes ❑ No* For tank systems tha ize the monitoring system as the primary tank overfill warning device (i.e. no <br /> Cl N/A mechanical overfill p ention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and op ting properly? if so,at what percent of tank capacity does the alarm trigger? % <br /> ❑ Yes* ❑ No Was any monit ng equipment replaced? If yes, identify specific sensors,probes,or other equipm7reed <br /> and list the ufacturer name and model for all replacement parts in Section E.below. <br /> p yes* ❑ No Was li ' found inside any secondary containment systems designed as dry systems? (Check aly) <br /> C1 puct; ❑Water. If yes,describe causes in Section E,below. <br /> ❑ Yes ElNo* s monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> [3 yes El No* s all monitoring equipment operational per manufacturer's specifications? <br /> *In Section7w,b ow,describe haw and when tlsese deficiencies were or will be corrected. <br /> E. Comments: <br /> 03/01 <br /> page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.