COMPLIANCE INFO_2008-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1103
>
2300 - Underground Storage Tank Program
>
PR0232587
>
COMPLIANCE INFO_2008-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 11:28:16 AM
Creation date
6/3/2020 9:58:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2010
RECORD_ID
PR0232587
PE
2361
FACILITY_ID
FA0004521
FACILITY_NAME
CHEVRON USA #201761*
STREET_NUMBER
1103
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
21935038
CURRENT_STATUS
01
SITE_LOCATION
1103 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232587_1103 S MAIN_2008-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
366
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> RESPONSE PLAN—PAGE 1 (One form per facility) <br /> TYPE OF ACTION ® 1.NEW PLAN ❑ 2.CHANGE OF INFORMATION Rol. <br /> L FACILITY INFORMATION, <br /> FACILITY ID#(Agency Use Only) <br /> BUSINESS NAME(Same as FACILITY NAME) Chevron Station#201761 Roz. <br /> BUSINESS SITE ADDRESS 1103 S.Main St. <br /> R03. CITY Manteca,CA 95337 R04. <br /> II SPILL CONTROL AND CLEANUP METHODS <br /> This plan addresses unauthorized releases from UST systems and supplements the emergency response plans and procedures in the facility's Hazardous Materials <br /> Business Plan. <br /> ➢ If safe to do so,facility personnel will take immediate measures to control or stop any release(e.g.,activate pump shut-off,etc.)and,if necessary,safely remove <br /> remaining hazardous material from the UST system. <br /> Any release to secondary containment will be pumped or otherwise removed within a time consistent with the ability ofthe secondary containment system to <br /> contain the hazardous material,but not greater than 30 calendar days,or sooner if required by the local agency.Recovered hazardous materials,unless still <br /> suitable for their intended use,will be managed as hazardous waste. <br /> ➢ Absorbent material will be used to contain and clean up manageable spills of hazardous materials.Absorbent material may be reused until it becomes too saturated <br /> to be effective.It will then be managed properly.Used absorbent material,reusable or waste,will be stored in a properly labeled and sealed container. <br /> Facility personnel will determine whether any water removed from secondary containment systems,or from clean-up activity,has been in contact with any <br /> hazardous material.If the water is contaminated,it will be managed as hazardous waste.If the water has a petroleum sheen(i.e.,rainbow colors),it is <br /> contaminated. A thick floating petroleum layer may not necessarily display rainbow colors.Water(hazardous or non-hazardous)from sumps,spill containers,etc. <br /> will not be disposed to storm water systems. <br /> We will review secondary containment systems for possible deterioration if any of the following conditions occur: <br /> 1. Hazardous material in contact with secondary containment is not compatible with the material used for secondary containment; <br /> 2. Secondary containment is prone to damage from any equipment used to remove or clean up hazardous material collected in secondary containment; <br /> 3. Hazardous material,other than the product/waste stored in the primary containment system,is placed inside secondary containment to treat or neutralize <br /> releasedproduct/waste,and the added material or resulting material from such a combination is not compatible with secondary containment. <br /> III.SPILL CONTROL AND CLEAN-UP EQUIPMENT <br /> PERIODIC MAINTENANCE:Spill control and clean-up equipment kept permanently on-site is listed in the facility's Hazardous Materials Business Plan.This <br /> equipment is inspected at least monthly,and after each use,supplies are replenished as needed.Defective equipment is repaired or replaced as necessary. <br /> EQUIPMENT NOT PERMANENTLY ON-SITE,BUT AVAILABLE FOR USE IF NEEDED:(Complete only if applicable) <br /> EQUIPMENT LOCATION AVAILABILITY <br /> ECS Spill Kit:Oil Absorbent Booms RIO no. R30. <br /> and Pads On-Site Safety Zone One-Time Use <br /> ECS Spill Kit: Motor Fuel Absorbent R11 R21. 131 <br /> Booms and Pads(White) On-Site Safety Zone One-Time Use <br /> R12 R22. R32 <br /> ECS Spill Kit:FM-186-2 On-Site Safe Zone 5 Gallon Back Stock <br /> R13. R23. R33 <br /> R14. R24. R34. <br /> R15. j R25. R35. <br /> IV.RESPONSIBLE PERSONS <br /> THE FOLLOWING PERSON(S)IS/ARE RESPONSIBLE FOR AUTHORIZING ANY WORK NECESSARY UNDER THIS RESPONSE PLAN: <br /> NAME Chevron Maintenance Dispatch R40. TITLE Solve One Help Desk 866-845-4254 R50. <br /> NAME Chevron EmeEgency EmergencyInformation Center <br /> R41. TITLE CEIC 800-231-0623 R51. <br /> NAME <br /> Raz. TITLE R52. <br /> NAME <br /> R43. TITLE R53. <br /> V.INDIRECT HAZARD DETERMINATION— , <br /> This information is required only when the presence of the hazardous substance can not be verified directly by the monitoring method used(e.g.,where liquid level <br /> measurements in a tank annular space or secondary piping are used as the basis for leak determination). <br /> THE FOLLOWING STEPS WILL BE TAKEN TO VERIFY THE PRESENCE OR ABSENCE OF HAZARDOUS SUBSTANCE IN THE SECONDARY <br /> CONTAINMENT IF MONITORING INDICATES A POSSIBLE UNAUTHORIZED RELEASE: R60. <br /> The affected UST System will be shut down for a third party precision test(s)to verify and isolate if a release has occurred. <br /> hwfwrc-e(9/24/04)-1/3 <br />