Laserfiche WebLink
0 SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.§jgov.gLqLehd/unitiii.htrn1 <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility address: Inspection Date: <br /> 1103 S Main Street, Manteca January 21, 2011 <br /> # Code Section VIOLATIONS V R <br /> HSC=CA Health&Safety Code;CCR=CA Code of Regulations;V=Violation; RV=Repeat Violation V <br /> Designated operator monthly inspection:(c)(1)alarms not documented;(c)(2-4)spill containers, <br /> 23c CCR 2715(c),(e) UDCS,and sumps(if necessary)not inspected;(c)(5)required test dates not checked or noted;(c)(6) <br /> employee training not verified;(e)monthly inspection reports not maintained on site for at least 12 <br /> months <br /> 23d CCR 2715(o Designated operator employee training:(1)not performed;(2)not current for at least one employee <br /> on site;(3)_Iog not kept <br /> Monitoring equipment certification: (a)not performed annually;(d)test report not submitted within 30 <br /> 24 CCR 2638 days;(e)test notification not provided to the EHD at least 48 hours prior to conducting an installation, <br /> repair, replacement,calibration,or certification;(0 performed,and failed to affix a tag/sticker on each <br /> monitoring equipment component that was certified,repaired,or replaced <br /> 25 HSC 25291(0 Annual line leak detector test not performed (MI) <br /> 26 HSC 25284.2 — Annual spill containment testing not performed <br /> 27 CCR 2636(0(4) Annual line tightness test not performed if positive shutdown or fail safe not present (MI) <br /> 28 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to permit (11112) <br /> conditions <br /> 29 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-Janus!y 1, 1984 (Mt <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-Janus 1, 1984) (MI) <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000'of public well,or failures not repaired and <br /> retested <br /> 32 CCR 2661 Permit to repair UST system not obtained <br /> 33 , HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 34 HSC 25298(b) Permit to temporarily close LIST system not obtained <br /> 35 HSC 25298(c) Permit to close UST system not obtained <br /> 36 HSC 25299(0(2) Tampering with or disabling leak detection devices or alarms <br /> 37 HSC 25298(a) Illegally abandoned UST system <br /> 38 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br /> 39 CCR 2631.1(a LIST system is not compatible with the substance stored <br /> Emergency generator systems <br /> 40 CCR 2636 ) Emergency generator monitoring system not checked daily or 129 not kept if no leak detector (Mi) <br /> 41 HSC 25281.5(b)(3) Unburied fuel piping not visually inspected at least monthly or log not kept (MI) <br /> AB 1702(2003-2004) HSC 25290.2(installed between 07/01/03 and 06/30104) <br /> VPH Systems HSC 25290.1 (installed on or after 07/01104) <br /> Compatibility and permeability requirements:(a)UST system is not compatible with the substance <br /> 42 CCR 2631.1 stored;(b)results of the compatibility and permeability testing requirements listed in subsections CCR <br /> 2631(bland(d)for a UST system installed after July 1,2004,were not submitted <br /> 43 HSC 25290.1 Primary containment not liquid or vapor tight <br /> HSC 25290.2(c)(1) <br /> 44 HSC 25290.1(c)(2) Secondary containment not liquid or vapor tight <br /> HSC 25290.2(c)(2) <br /> 45 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2(c 3 <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or (mi) <br /> HSC 25290.2(d) the entry of liquid or vapor from the primary containment into the secondary containment <br /> 47 HSC 25290.1(e) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial (mi) <br /> space of the LIST system not maintained <br /> HSC 25290.1 LIST system not tested by one of the following methods prior to use: (1)Enhanced leak detection;(2) <br /> 48 6) inert gas pressure test approved by SWRCB;(3)test method deemed equivalent to(1)or(2)by the <br /> HSC 25290.2(i) SWRCB <br /> Other violations <br /> 999 Other. See attached"Continuation-Official Inspection Report"for violation(s)not listed above. <br /> EHD inspector. Phone: UIC <br /> A4. &*1jW4 (209) 468-3439 Septic system: <br /> n Serves->20 people/day <br /> Received by: Title: 11 Receives other than sanitary waste <br /> Other disposal methods: <br /> Lecsd C"V)•e f Cl Dry wells/French Drains <br /> 2-002 REV 08113/10 Page 2 UST INSPECTION REPORT <br />