COMPLIANCE INFO_1989-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MICHAEL CANLIS
>
7000
>
2300 - Underground Storage Tank Program
>
PR0504967
>
COMPLIANCE INFO_1989-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2023 1:40:41 PM
Creation date
6/3/2020 9:58:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1989-2013
RECORD_ID
PR0504967
PE
2361
FACILITY_ID
FA0006440
FACILITY_NAME
SHERIFFS OPERATIONS CTR #2
STREET_NUMBER
7000
Direction
N
STREET_NAME
MICHAEL CANLIS
STREET_TYPE
BLVD
City
FRENCH CAMP
Zip
95231
APN
19305014
CURRENT_STATUS
01
SITE_LOCATION
7000 N MICHAEL CANLIS BLVD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0504967_7000 N MICHAEL CANLIS_1989-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
571
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLUMBING — To make install easier and to can - <br />serve adhesive, all measuring, tting, and tapering <br />should be done first. Then proceed with the bonding op- <br />eration. To make sure measurements are right, assemble <br />the entire piping system "dry" (without adhesive) before <br />bonding. Where accuracy is important, "dry" assembly is <br />a must. For close tolerance piping refer to A. O. Smith - <br />Inland Installation Manual No. 9474. <br />FLEXIBLE HOSE CONNECTIONS — Flexible hose con- <br />nections can be installed in product and vent lines at the <br />point where they leave the tank. On suction pump installa- <br />tion they can be put in just before the pump riser. Use of <br />flexible connections can prevent breaking of lines or fit- <br />tings where settlement might cause tank movement, or <br />where expansion and contraction might cause movemen4 <br />of the pipe. <br />The drawings of typical island piping indicate how con- <br />nections can be made using standard RED THREAD R <br />adapters. <br />14i RED THREAD II pipe is inherently flexible. API Publication 1615 states: <br />"Fiberglass piping, which is inherently flexible, does not require swing joints, <br />if at least 4 feet of straight run is provided between any directional change <br />exceeding 30*." <br />BURIAL — Minimum acceptable burial depths are given <br />in this section. In some cases greatest depths may be <br />required by the authority having jurisdiction or by local <br />codes. <br />The maximum allowable burial depth is 24 feet for burial <br />in moderately compacted soils which do not contain clay <br />and where the soil modulus is at least 1000 psi. <br />Minimum burial depths shown in the above burial table <br />are acceptable if, and only if, the ditch width is 2.5 feet or <br />less; the paved surfaces extend at least 2 feet on either <br />side of the ditch; the fill material is clean sand or 1/s" to <br />3/4" pea gravel and 6" of the fill material is placed under <br />the pipe as bedding material. <br />Remaining backfill above Sand or Pea Gravel amounts <br />as shown in the last column of the burial table can be <br />native soil if desired. <br />If burial conditions other than those discussed above <br />exist, contact A. O. Smith -Inland Inc. <br />REPAIRING — On rare occasions it may be necessary to <br />repair a damaged section of RED THREAD II pipe. Where <br />damage is in the form of a puncture, the pipe can be <br />repaired using a patch made from the pipe itself. If a <br />considerable length of pipe is involved, it is best to re- <br />place it with a new section of pipe. Complete information <br />for making repairs are included in the A. O. Smith -Inland <br />Inc. Installation Instructions Manual No. 1055. <br />It is the policy of A. O Smith -Inland Inc. to improve its products continually. In <br />accord with that policy, the right is reserved to make changes in specifica- <br />tions, descriptions and illustrative material contained in this bulletin as condi- <br />tions warrant. The information in this bulletin does not constitute a stated or <br />implied guarantee. <br />- \/ <br />
The URL can be used to link to this page
Your browser does not support the video tag.