My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
10842
>
2300 - Underground Storage Tank Program
>
PR0505615
>
COMPLIANCE INFO_1995-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2024 1:45:30 PM
Creation date
6/3/2020 9:58:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-2011
RECORD_ID
PR0505615
PE
2361
FACILITY_ID
FA0006898
FACILITY_NAME
RAMOS OIL-FRENCH CAMP
STREET_NUMBER
10842
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19333028
CURRENT_STATUS
01
SITE_LOCATION
10842 S HARLAN RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505615_10842 S HARLAN_1995-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
471
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)488-3420 Fav(209)468-3433 Web:www.sigov.QMLehd/unitiii.htmI <br /> CONTINUATION FORM Page: 3 of 4 <br /> OFFICIAL INSPECTION REPORT Date: 10/07/10 <br /> Facility Address: Ramos Oil-French Camp 10842 S. Harlan Rd, French Camp Program: UST <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> UST Inspection: Routine and Monitoring System Certification <br /> #23c. The designated operator failed to document the following alarms- October 1, 09 Mstrl-2 sIv 1, <br /> Master 3-4, Slave 2-3, Sens Loss of Signal, Power Up and Down,- October 13, 09 Power Up and Power <br /> Down; November 16, 09 Power Up and Down; February 7, 10 Power Up and Down; August 25, 10 <br /> System Fail Float Missing; September 23, 10 System Fail Float Missing. Failed to check that the alarms <br /> were responded to appropriately on the appropriate designated operator monthly inspection reports. <br /> During the monthly inspection, the designated operator shall review the alarm history for the previous <br /> month, check that each alarm was documented and responded to appropriately, and attach a copy of <br /> the alarm history with documentation taken in response to any alarms to the monthly report. Ensure that <br /> designated operators performing monthly inspections at this facility are including all of the required <br /> information on the reports. <br /> 23c. The designated operator failed to check and note the complete test dates for the Monitoring System <br /> Certification, Spill Bucket testing and Secondary containment testing on the reports from July 2009 to <br /> present designated operator monthly inspection reports. Since July 2009, test dates are documented as <br /> Month and Year rather than Month, Day and Year. Documenting which day of the month will help the <br /> designated operator differentiate if an alarm had occur on a day a certification or a repair was done <br /> compared to a day no repairs or testing was done. During the monthly inspection, the designated <br /> operator shall check that all required testing and maintenance for the UST system have been completed <br /> and document the dates they were done. Ensure that designated operators performing monthly <br /> inspections at this facility are including all of the required information on the reports. <br /> 23c. The March 2010 designated operator monthly inspection report was not found on site. Designated <br /> operator monthly inspection reports for the previous twelve months shall be retained on site. Locate and <br /> ensure that copies of the previous twelve months of designated operator monthly inspection reports are <br /> maintained on site. Submit copy of March 2010 DO report along with copy of the March 2010 alarm <br /> history report print out from Incon monitoring panel to the EHD by November 8, 10. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY PATE($122). <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHDS CURRENT HOURLY RATE. <br /> EHD In or <br /> Received By: Title: <br /> EHD N*�2-003 Rev 10/10 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.