My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
437
>
2300 - Underground Storage Tank Program
>
PR0506406
>
COMPLIANCE INFO_1996-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/17/2023 3:00:08 PM
Creation date
6/3/2020 9:58:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2008
RECORD_ID
PR0506406
PE
2361
FACILITY_ID
FA0002313
FACILITY_NAME
WILSON WAY CHEVRON
STREET_NUMBER
437
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15113052
CURRENT_STATUS
01
SITE_LOCATION
437 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506406_437 N WILSON_1996-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
469
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> D. Results of Testing/Servicing <br /> Software Version Installed: 11.02 <br /> Complete the follo ' checklist., <br /> 1 0 Yes I E]No, Is the audible alarm operational? <br /> Z Yes No Is the visual alarm operational? <br /> Yes No Were all sensors visually inspected,functionally tested. <br /> Yes ®No Were all sensors installed at lowest point of secondary cuntamn;f:id and posilionod _-;r, flhat othrf cquipment will <br /> not interfere with their 2ropfr o22ration? <br /> —Yes E]No if alarms are relayed to a remote monitoring station,is all conrinunications equipment(e.kj,wo(ielm)opeTahorial? <br /> I E] N/A <br /> Yes No For pressurized piping systems, does the turbine autoffiaticaily shut dawn if the piping secondary (,ontainrnent <br /> El NIA monitoring system detects a leak, fails to operate, or is elef Jr cilly disconne(Aed? it yes which s?-isois witiale <br /> positive shut down? (Check a#that appiy) M Sumpffref)(11 ser.sors:1 Dispenser (_-untainrnent Senors, <br /> Did you confirm positive shut down due to leaks and sensores 7] <br /> Y Nu, <br /> [:1 Yes ®No For tank systems that utilize the monitoring system as tho primapy lank overfillwarning device 0 0, no mechanical <br /> El NIA overfill prevention valve is installed), is the over-fill warming alarm visiblo and audibte at the tank fill i)nint(s) and <br /> I <br /> erly? If yes,at what percent of Lar-1kcap!i�,iti -�—Jo o ealarm lnwoii?__ <br /> 0 Yes [ o Was any monitoring equipment replaced? If yes, idenHy specific s(!nsors, iirnbes, or other rf�tflaced <br /> and list the manufacturer name and model f2einefil hart_,in Section F,hel(Ylv. <br /> L�� <br /> Yes ONo Was liquid found inside any secondary containment sysierns designed as(Iry systems? <br /> Product;[]Water 10. If yes,describe causes inSectionE.below, <br /> (0-Yes No Was monitoring system set-up reviewed to ensure proper settrngs?Attach"'ei LIP felmrt' it applicable, <br /> Yes ®No [sail monitoring equipment operational per <br /> In section E below,describe how and when these deficiencies were or will be corrected <br /> E. Comments: <br /> Small amount of water in both fill sumps, most likely from the spill containers that tailed. <br /> Veeder Root stand alone sensors are used for the dispenser containment monitoring. !"he sensors shut down the <br /> Dispensers only and will shutdown the dispenser upon disconnection also. <br /> Site does not have an audible/visual overfill alarm at the tank pad. However, the fill sumps are monitored and ball floats <br /> have been installed. <br /> Page 2 of 3 <br />