My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
437
>
2300 - Underground Storage Tank Program
>
PR0506406
>
COMPLIANCE INFO_1996-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/17/2023 3:00:08 PM
Creation date
6/3/2020 9:58:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2008
RECORD_ID
PR0506406
PE
2361
FACILITY_ID
FA0002313
FACILITY_NAME
WILSON WAY CHEVRON
STREET_NUMBER
437
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15113052
CURRENT_STATUS
01
SITE_LOCATION
437 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506406_437 N WILSON_1996-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
469
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Praxair Services, Inc. <br /> 3755 N. Business Center Drive <br /> Tucson,AZ 85705 <br /> Tel: (800)394-9929 <br /> Fax: (520)293-1306 <br /> IN SERVICE ENHANCED LEAK DETECTION (1 L ) <br /> TEST RESULTS <br /> Client Date: 2/22/2006 Site Info: Job No: 38731 EL <br /> CGRS Wilson Way Chevron <br /> 5444 Dry Creek Rd. 431 N. Wilson Way <br /> Sacramento, CA 95838 Stockton, CA 95205 <br /> TEST SUMMARY <br /> Praxair Services conducted Enhanced Leak Detection testing on February 20 -22,2006.An additional <br /> sample event was also performed on February 25, 2006 to evaluate in ground detections that occurred <br /> during original site visit. <br /> 2/20/2006 <br /> Arrived site:7:45 -Site consists of Two (12,000 gallon) Under Ground Storage Tanks and Four dispensers. <br /> The product piping is double wall Smith Fiberglass (2 inch Primary/3 inch Secondary).The vent and vapor <br /> recovery piping is single wall Smith Fiberglass-3 inch Primary. <br /> Upon review, no secondary access was available on the product piping within the dispensers.Attempts were <br /> made to confirm communication without trying to reconfigure the secondary boots-No good method could <br /> be established- It was determined that steps needed to be taken to install access ports within dispensers- <br /> CGRS will create access.While secondary accesses were being installed, pre-testing continued on the tank <br /> top fittings,sumps and hydro testing of spill buckets.One leak was found and repaired on a nipple within the <br /> 87 turbine sump.Two repairs were also made on the spill bucket drain and swivel adapter.A leak simulation <br /> was introduced into the ground to determine tracer migration and test time frames.All spill bucket passed <br /> the hydro test. CGRS has all but one dispenser equipped with secondary access-OFF SITE:6:45 pm <br /> 2/2112006 <br /> ON SITE: 8:00 am- Samples collected from vertical probe system confirmed Leak Simulation movement at <br /> adequate concentration and distance in 24 hours. CGRS completed secondary access install in final <br /> dispenser.Tracer was introduced into tanks at 12:00 pm and was detected in fuel samples collected of each <br /> product at target concentrations at the dispensers by 3:45 pm. Samples collected from the secondary of the <br /> product lines showed no detection of tracer and both 87 and 91 product primary lines pass. Samples <br /> collected from tank sumps and Under Dispenser containments (UDCs)show no detection of tracer.All pipe <br /> fittings and connections within these sumps pass. Based on Leak Simulation results, sampling of the probe <br /> system needs to occur 24 hours after the introduction of tracer into the tanks-Will return to complete final <br /> sample event at 12 pm on 2/22. OFF SITE: 6:45 pm <br /> 2 of 3 38731 EL QA Retest MDC Report-Cert.xls <br />
The URL can be used to link to this page
Your browser does not support the video tag.