EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0507837
PE
2361
FACILITY_ID
FA0008057
FACILITY_NAME
TRACY TRUCK AND AUTO STOP
STREET_NUMBER
3940
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95304
APN
21220004
CURRENT_STATUS
01
SITE_LOCATION
3940 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0507837_3940 N TRACY_2011-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
517
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 16 of / <br /> 7. UNDER-DISPENSER CONTAINMENT C TESTING <br /> Test Method Developed By: ❑UDC Manufacturer X Industry Standard ❑Professional Engineer <br /> X Other(Spec) Incon <br /> Test Method Used: ❑Pressure ❑Vacuum X Hydrostatic <br /> Other(Spec) <br /> Test Equipment Used: Incon TS-STS Sump Test System Equipment Resolution: .002 <br /> UDC#17/18 UDC# UDC# UDC# <br /> UDC Manufacturer: Bravo <br /> UDC Material: Steel <br /> UDC Depth: 12" <br /> Height from UDC Bottom to Top 1" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 1" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Dirty <br /> testing: <br /> Portion of UDC Tested' 1/3 <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both 0 Yes ❑No X NA ❑Yes ❑No ❑NA 0 Yes 0 No ❑NA 0 Yes 0 No ❑NA <br /> product and water)?' <br /> Turbine shutdown response time N/A N/A N/A N/A <br /> Is system programmed for fail- ❑Yes ❑No X NA 0 Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> safe shutdown?® <br /> Was fail-safe verified to be 0 Yes 0 No X NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA 0 Yes ❑No ❑NA <br /> operational?* <br /> Wait time between applying 5 Minutes <br /> pressure/vacuum/water and <br /> starting test <br /> Test Start Time: 1:36 PM <br /> Initial Reading(RI): 0.5984" <br /> Test End Time: 1:51 PM <br /> Final Reading(RF): 0.5979" <br /> Test Duration: 15 Minutes <br /> Chane in Reading(RF-RI): -0.0005 <br /> Pass/Fail Threshold or Criteria: +/-0.002 <br /> �" :r�1`�'"�a�'�F r 4u��yt'�s�.s,;�� ���olPr "ZEr^` �� " � v�� <br /> " $ Re, u1t " ait5 t 5i,e,. ' � ,'p$§S_ :'l )Fall! }xp$ 5 CI I'$fl ' 5 tY$S Frul, s E rt51 I <br /> 0 Yes 0 No X NA ❑Yes 0 No [INA , ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor removed for testing? <br /> Was sensor properly replaced and 0 Yes ❑No X NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA 0 Yes ❑No ❑NA <br /> verified functional after testin ? <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 0 9 2015 <br /> ENVIKUNMtNT At, <br /> 'If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br /> I <br />