COMPLIANCE INFO_1999-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_1999-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2021 10:06:56 AM
Creation date
6/3/2020 9:59:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2005
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515365_120 FRANK WEST_1999-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
458
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Read all Inst ons and operating guidelines before allation. <br /> To Installer: Before installation, read Installation Manual and Operating Guidelines. After installation, <br /> give Installation Manual and Operating Guidelines to owner. <br /> To Owner: After installation, retain Installation Manual and Operating Guidelines for future reference to <br /> operating guidelines. <br /> 1.2.GENERAL <br /> 1.2.1. It is important to follow the procedures and instructions in <br /> 1.1.SAFETY this manual in order to safely and properly install a Xerxes <br /> 1.1.1.Before beginning the tank installation,read through the underground storage tank and accessories.Failure to follow <br /> entire Installation Manual and Operating Guidelines(subse- these instructions will void the tank warranty and may cause <br /> quently referred to as"Installation Manual").It is the responsibil- tank failure,serious personal injury or property damage. <br /> ity of the owner,installer and operator to comply with all federal, <br /> state and local laws,regulations,codes and safety precautions. 1.2.2.The Xerxes warranty applies only to a tank installed <br /> according to these instructions.Since Xerxes does not control <br /> 1.1.2.No instructions or procedures presented in this Installation the parameters of any installation,Xerxes'sole responsibility in <br /> Manual should be interpreted so as to put at risk any person's any installation is that presented in our warranty. <br /> health or safety,or to harm any property or the environment. 1.2.3. It is the responsibility of the owner and operator to always <br /> 1.1.3.Keep the Installation Manual available at the installation follow the operating guidelines set forth in Xerxes'applicable <br /> site to refer to safety procedures as needed. warranty and Section 18 of this Installation Manual.A Xerxes <br /> warranty is found in each product brochure or is available upon <br /> 1.1.4.Working in excavations is dangerous,and is regulated by request from the UST coordinator at the Xerxes plant nearest <br /> both federal and state safety regulations. you. It is the responsibility of the owner to retain this Installation <br /> Manual for future reference to operating guidelines. <br /> 1.1.5.Careless activity or operation of equipment can cause <br /> death,serious personal injury or property damage. 1.2.4.Use the Tank Installation Checklist(included in this <br /> manual)for all single-wall tanks(SWT),double-wall tanks <br /> 1 (DWT),oil/water separators(OWS)and multicompartment tanks <br /> Follow OSHA regulations for tank excavations. (MCT)as the installation proceeds.Retain a copy of the <br /> Collapse of <br /> excavation walls could result in death, serious personal completed Tank Installation Checklist,and any correspondence, <br /> injury or property damage. certification,etc.,related to the tank.Each tank requires a <br /> separate Tank Installation Checklist.Consult your Xerxes <br /> 1.1.6.The following definitions will serve as a guide when representative or distributor if additional Tank Installation <br /> reading the Installation Manual: Checklist forms are needed. <br /> E 1.2.5.The tank owner and/or installing contractor should retain a <br /> Indicates an imminently hazardous situation, which, if not copy of the Tank Installation Checklist to facilitate any warranty <br /> avoided, will result in death, serious personal injury or claim. <br /> property damage. <br /> 1.2.6.Comply with all applicable regulations and standards, <br /> AWARNsuch as: <br /> 1 • federal,state and local construction,health,safety and <br /> Indicates a potentially hazardous situation, which, if not environmental codes; <br /> avoided, could result in death, serious personal injury or ° National Fire Protection Association standards(for example, <br /> property damage. NFPA 30,30A and 31); <br /> • industry standard practices(for example, PEI RP100,API <br /> RP1615); <br /> ACAUT1 • EPA reference materials(for example,"Doing It Right"). <br /> Indicates a potentially hazardous situation, which, if not <br /> avoided, may result in minor or moderate personal injury or 1.2.7. For additional information,contact your state,county and <br /> property damage. It may also be used to alert against city storage-tank authorities,including health,fire or building <br /> unsafe practices. departments,and environmental agencies.All work must be <br /> performed according to standard industry practices and OSHA <br /> regulations. <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.