My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_1999-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2021 10:06:56 AM
Creation date
6/3/2020 9:59:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2005
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515365_120 FRANK WEST_1999-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
458
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> Probe and Sensor Installation Probe and Sensor Installation Diagrams <br /> Vent tube-CAUTION-tube must 14"min.dia. <br /> remain clear. If vent tube is manhole <br /> blocked,damage may occur to tank. Cord grip <br /> Concrete slab -7= z <br /> or packed earth <br /> per NFPA 80 <br /> Riser pipe cap Seal-off <br /> Adjustable lead cable f 1/2°rigid conduit(to Console) <br /> Single float hydrostatic sensor Weatherproof junction <br /> box with 1/2-inch N.P.T. <br /> Riser pipe threads(16 Cubic inch <br /> Low liquid level alarm float volume minimum) <br /> (must be submerged in brine FRP reservoir(Please check with <br /> solution). ____ _ ______ tank manufacturer on how to set the <br /> brine level in the reservoir) <br /> Double-wall tank�y <br /> sensorsftnstlt.eps <br /> Item F.-Typical Hydrostatic Reservoir Single Float Sensor Installation <br /> Vent tube-CAUTION-tube must <br /> remain clear. If vent tube is blocked, 14"min.dia. <br /> damage may occur to tank. manhole�I Cord grip <br /> i 1 <br /> Concrete slab <br /> e <br /> or packed earth o ... <br /> per NFPA 80 G y1.P <br /> Riser pipe cap Seal-off <br /> Adjustable lead cable 1/2"rigid conduit(to Console) <br /> Dual float hydrostatic sensor Weatherproof junction <br /> box with 1/2-inch N.P.T. <br /> Riser pipe threads(16 Cubic inch <br /> High liquid level alarm float volume minimum) <br /> Low liquid level alarm float(brine FRP reservoir(Please check with <br /> level must be between two floats). tank manufacturer on how to set the <br /> brine level in the reservoir) <br /> - Double-wall tank <br /> sersors\hsins0.eps <br /> Item G.-Typical Hydrostatic Reservoir Dual Float Sensor Installation <br /> Figure 5. TLS-350 Probe and Sensor Installation Diagrams-cont'd. <br /> 19 <br />
The URL can be used to link to this page
Your browser does not support the video tag.