Sealing Field Connections <br /> Wiring Run Through Rigid Conduit <br /> 1. Pull the wires from the probe or sensor into the junction box.Pull the two or three <br /> wires from the console through the seal-off box,the conduit attaching the junction <br /> box to the seal-off box and into the junction box. <br /> 2. Using wire nuts,connect the two or three wires from the probe or sensor to the two <br /> or three wires coming from the console.Be sure to observe color codes or tags to <br /> when making these connections so that the sensor or probe outputs are attached to <br /> the correct terminals on the corresponding console module [Figure 8]. <br /> 3. Seal wire nuts with epoxy sealant following the instructions in Figure 9. <br /> CAUTION: Epoxy sealant may be irritating to eyes and skin. May cause skin <br /> sensitization in susceptible individuals. May be absorbed through the skin. <br /> Epoxy sealant contains epoxy resin and vinyl cyclohexane dioxide. Vinyl <br /> cyclohexane dioxide has caused skin cancer in animal tests. Avoid eye and <br /> skin contact.Wear chemically resistant gloves and safety glasses. Use only in <br /> well ventilated areas. <br /> 4. Do NOT terminate shield or drain wire at this location,ground shield and drain <br /> wires at console only. <br /> 5. Push the tie-wrapped,epoxy sealed bag into the junction box.Replace and tighten <br /> the junction box cover. <br /> Direct Burial Cable <br /> When using direct burial cable for probe-or sensor-to-console wiring runs,the sealing <br /> materials and procedure are completely different. <br /> 10 If you are using Direct Burial Cable you must follow the sealing instructions in <br /> the Veeder-Root Direct Burial Cable Installation Manual,P/N 576013-858. <br /> 31 <br />