My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_2006-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2021 1:42:31 PM
Creation date
6/3/2020 9:59:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2009
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRANK WEST\120\PR0515365\SUMP REPAIR 2008.PDF
QuestysFileName
SUMP REPAIR 2008
QuestysRecordDate
11/10/2015 5:47:54 PM
QuestysRecordID
2922518
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
362
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 5. <br /> 7. UNDER-DISPENSER CONTAINMENT (UDC)TESTING <br /> Test Method Developed By: ❑ UDC Manufacturer F-1 Industry Standard �X Professional Engineer <br /> El Other (Specify) <br /> Test Method Used: F] Pressure F Vacuum ❑X Hydrostatic <br /> Other (Specify) <br /> Test Equipment Used: vp 1 t Equipment Resolution: <br /> UDC# <br /> 1/2 UDC# 3/4 UDC# UDC# <br /> UDC Manufacturer: unknown unknown <br /> UDC Material: fiberglass fiberglass <br /> UDC Depth: 3211 32" <br /> Height from UDC Top to Top of 1011 10" <br /> Highest Piping Pentration: <br /> Height from UDCTop to Lowest 811 811 <br /> Electrical Pentration: <br /> Condition of UDC prior to testing: good good <br /> Portion of UDC Tested: I 1211 1211 <br /> Does turbine shut down when <br /> sump sensor detects liquid(bothryes E_1No❑N [fl' Yes 1:1NoE]N [::]Yes❑NoDN Yes F]NoE]N <br /> product and water)?* <br /> Turbine shutdown response time: 2-5 secs 2-5 sec s <br /> Is system programmed for fail-safe � ❑ � [:]Yes <br /> ❑ � ❑ ❑ [:] <br /> shutdown?* Yes N N X❑Yes N N Yes N N Yes No <br /> Was fail-safe verified to be Yes❑No❑N E]Yes ONoON Yes❑No❑N Yes❑No�T <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 min 5min <br /> test: <br /> Test Start Time: 9:30 9:40 <br /> Initial Reading(RI): 9.932 9.243 <br /> Test End Time: 9:45 9:55 <br /> Final Reading(RF): -13.679 9.243 <br /> Test Duration: 15 min 15 min <br /> Change in Reading(RF-RI ): 2.81gph .000gph <br /> Pass/Fail Threshold or Criteria: 05gph .05gph <br /> Was sensor removed for testing? X Yes N NA X Yes N NA Yes N NA Yes No <br /> Was sensor properly replaced and � Ely <br /> ❑ ❑ <br /> verified functional after testing? Yec] NA Ye N NAe N NA Yes N <br /> Comments- (include informatiery on repairs made prior to testing, and recommended follow-up for failed tests) <br /> starting and ending values are taken off the vp t an use to ca u ate the GPH <br /> 1 If the entire depth of the UDC is not tested,specify how much was tested.If the answer to anv of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />