My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2000-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1330
>
2300 - Underground Storage Tank Program
>
PR0515864
>
COMPLIANCE INFO_2000-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2024 2:09:22 PM
Creation date
6/3/2020 9:59:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2009
RECORD_ID
PR0515864
PE
2361
FACILITY_ID
FA0012355
FACILITY_NAME
A&A GAS FOOD MART
STREET_NUMBER
1330
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120053
CURRENT_STATUS
01
SITE_LOCATION
1330 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515864_1330 E YOSEMITE_2000-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 7 of 9 0/r <br /> � <br /> 9. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard ❑ Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum 0 Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Caldwell Level Change Indicator Equipment Resolution: 0.0025 <br /> IMI Fill Sump # 1 Fill Sump # 2 Fill Sump # 3 Fill Sump # <br /> Sump Diameter: 46" 46" 46" <br /> Sump Depth: 71" 68" 68" <br /> Height from Tank Top to Top of 0 0 0 <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 40" 40" 40" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: D D D <br /> Portion of Sump Tested 30% 30% 30% <br /> Sump Material: F.G F.G F.G <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5min 5min 5min <br /> test: <br /> Test Start Time: 3:40 prn 3:30 prn <br /> Initial Reading Ri): 0.0025 0.0025 <br /> Test End Time: 4:10 prn 4:00 prn <br /> Final Reading(RF): 0.0025 0.0025 <br /> Test Duration: 1hr 1hr <br /> Change in Reading(RF-Ri): 0 0 <br /> Pass/Fail Threshold or Criteria: 1/16 hr 1/16 hr <br /> Test Result: ❑ Pass...M,Fail 21 Pass ❑ Fail I] Pass ❑ Fail ❑ Pass ❑ Fail <br /> Is there a sensor in the sump? ❑Yes ❑ No ®Yes ❑ No ®Yes ❑ No ❑Yes ❑ No <br /> Does the sensor alarm when either ❑Yes ❑ No ❑ NA 91Yes ❑ No ❑ NA ❑x Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA <br /> product or water is detected? <br /> Was sensor removed for testing? ❑Yes ❑ No ❑ NA ©Yes ❑ No ❑ NA ©Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA <br /> Was sensor properly replaced after ❑Yes ❑ No ❑ NA I]Yes ❑ No ❑ NA O Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA <br /> testing? <br /> Comments—(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.