Laserfiche WebLink
Monitorh#System Equipment4oertification <br />For Use By All Jurisdictions Within The State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br />prepared for each monitoring system control panel by the technician who performs the work.A copy of this form must be provided <br />to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST system <br />within 30 days of test date. <br />A. General Information <br />Facility Name: Yosemite Shell <br />Site Address: 1330 E. Yosemite @ Highway 99 <br />Facility Contact Person: <br />City: Manteca, CA <br />Bldg. No.: <br />Zip: 95336 - <br />Contact Phone No.: (209) 825-0332 <br />Make/Model of Monitoring System: ? -F\,, S _ 3 r J / 1I Date of Testing/Servicing;Sf84_� <br />B. Inventory of Equipment Tested/Certified '7 P z <br />Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />Tank ED: 01 -Rego <br />Tank 02 -Prem <br />ID: <br />0 In - Tank Gauging Probe. <br />Model: <br />VR 847390-10e <br />0 In - Tank Gauging Probe. <br />Model: <br />yR 847390-109 <br />/Annular Space or Vault Sensor. <br />Model: <br />VR 794390-409 <br />2,1 Annular Space or Vault Sensor. <br />Model: <br />—VR 794390.409 <br />Piping Sump \ Trench Sensor (s). <br />Model: <br />VR 794380-352"0' <br />Piping S ump \Trench Sensor (s). <br />Model: <br />VR 794380.368• � 'Z <br />Fill Sump Sensor (s). <br />Model: <br />VR 794380462- -ZOO <br />Fill Sump Sensor (s). <br />Model: <br />VR 794380362- zas <br />Mechanical Line Leak Detector. <br />Model: <br />vaporiess LD2000 <br />0 Mechanical Line Leak Detector. <br />Model: <br />vaporiess LD2000 <br />0 Electronic Line Leak Detector. <br />Model: <br />None <br />0 Electronic Line Leak Detector. <br />Model: <br />None <br />0 Tank Overfill \ High -Level Sensor. <br />Model: <br />None <br />0 Tank Overfill \ High -Level Sensor. <br />Model: <br />None <br />Other ( specify equipment type and model in Section E on Page 2). <br />0 Other ( specify equipment type and model in Section E on Page 2). <br />Tank ID: 03 -Diesel <br />Tank ED: <br />0 In - Tank Gauging Probe. <br />Model: <br />VR 847390-109 <br />0 In - Tank Gauging Probe. <br />Model: <br />? <br />Annular Space or Vault Sensor. <br />Model: <br />VR 794390-409 <br />0 Annular Space or Vault Sensor. <br />Model: <br />? <br />Piping Sump \ Trench Sensor (s). <br />Model: <br />VR 794380352 <br />0 Piping Sump \ Trench Sensor (s). <br />Model: <br />? <br />o Fill Sump Sensor (s). <br />Model:VR 7943804=Z <br />0 Fill Sump Sensor (s). <br />Model: <br />? <br />rY Mechanical Line Leak Detector. <br />i� <br />Model: <br />vaporiess LD2000 <br />0 Mechanical Line Leak Detector. <br />Model: <br />? <br />Electronic Line Leak Detector. <br />Model: <br />None <br />0 Electronic Line Leak Detector. <br />Model: <br />? <br />0 Tank Overfill \ High -Level Sensor. <br />Model: <br />None <br />0 Tank Overfill \ High -Level Sensor. <br />Model: <br />? <br />0 Other( specify equipment type and model in Section Eon Page 2). <br />0 Other ( specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 01-02 <br />p <br />Dispenser ID.. 03-04 <br />ispenser Containment Sensor (s). <br />Model: <br />VR 794380322 <br />spenser Containment Sensor (s). <br />Model: <br />VR 794380322 <br />0 Shear Valve (s). <br />0 Shear Valve (s). <br />0 Dispenser Containment Float (s) and Chain (s). <br />Dispenser Containment Float (s) and <br />Chain (s). <br />Dispenser E. 05-06 <br />Dispenser ID• 07-0$ <br />Dispenser Containment Sensor (s). <br />Model: <br />VR 784380322 <br />Dispenser Containment Sensor (s). <br />Model: <br />VR 794380322 <br />0 Shear Valve (s). <br />0 Shear Valve (s). <br />0 Dispenser Containment Float (s) and Chain (s). <br />0 Dispenser Containment Float (s) and <br />Chain (s). <br />Dispenser ID: 09-10 <br />p <br />Dispenser ID: 11-12 <br />/Dispenser Containment Sensor (s). <br />Model: <br />VR 794380-322 <br />n�,Dispenser Containment Sensor (s). <br />Model: <br />VR 794380322 <br />0 Shear Valve (s). <br />0 Shear Valve (s). <br />0 Dispenser Containment Float (s) and Chain (s). <br />0 Dispenser Containment Float (s) and Chain (s). <br />If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br />manufacturer's guidelines. Attached to this Certification is information (e.g. manufactures' checklists ) necessary to verify that this <br />information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br />reports, I have also attached a copy of the; (check all that apply): eff System set-up � Alarm history report <br />Technician Name (print):SSS-JoshH Signature: <br />Certification No.: c'�56. License. N4 4 <br />Testing Company Name: Ser. Sta. Sys. Phone No.: (408) 971-2445 <br />Site Address: 1330 E. Yosemite @ Highway 99 Date of Testing/Servicing: 71SX4 <br />-7f <br />