COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1330
>
2300 - Underground Storage Tank Program
>
PR0515864
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 10:44:40 AM
Creation date
6/3/2020 10:00:02 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0515864
PE
2361
FACILITY_ID
FA0012355
FACILITY_NAME
A&A GAS FOOD MART
STREET_NUMBER
1330
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120053
CURRENT_STATUS
01
SITE_LOCATION
1330 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515864_1330 E YOSEMITE_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
486
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 p <br /> f , 0 <br /> Elite IV Contractors <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑Tank Manufacturer X Industry Standard ❑ Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: X Pressure ❑Vacuum ❑ Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Pressure Gauge Equipment Resolution: <br /> EMMEMFTank#1 87 Tank#2 91 Tank#3 DIE Tank# <br /> Is Tank Exempt From Testing?' ❑Yes X No ❑Yes X No ❑Yes X No ❑Yes ❑No <br /> Tank Capacity: 20,000 10,078 10,078 <br /> Tank Material: Fiberglass Fiberglass Fiberglass <br /> Tank Manufacturer: <br /> Product Stored: 87 91 j „ <br /> Wait time between applying <br /> pressure/vacuum/water and 15 Min 15 Min 15 Min <br /> starting test: f0 \y ) I ?(l i <br /> Test Start Time: 1200 1200 1200 <br /> Initial Reading(Rj): 3 PSI 3 PSI 3 PSI S ' <br /> Test End Time: 100 100 100 <br /> Final Reading(RF): 3 PSI 3 PSI 3 PSI <br /> Test Duration: 1 HR 1 HR l HR <br /> Change in Reading(RF-Rj): 0 0 0 <br /> Pass/Fail Threshold or Criteria: 1/16 PSI 1/16 PSI 1/16 PSI <br /> Test Result: X Pass ❑Fail X Pass ❑Fail X Pass ❑Fail 0 Pass ❑Fall <br /> Was sensor removed for testing? ❑Yes NXANo ❑ ❑Yes X No ElNA F1Yes ElNo ElNA L1 Yes ❑No LlNA <br /> Was sensor properly replaced and ❑Yes ❑No X NA ❑Yes ❑No X NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Water used for testing was put back into test trailer barrels for future use on nest test site. <br /> ' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {California Code of Regulations,Title 23, Section 2637(a)(6)1 <br />