My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1330
>
2300 - Underground Storage Tank Program
>
PR0515864
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 10:44:40 AM
Creation date
6/3/2020 10:00:02 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0515864
PE
2361
FACILITY_ID
FA0012355
FACILITY_NAME
A&A GAS FOOD MART
STREET_NUMBER
1330
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120053
CURRENT_STATUS
01
SITE_LOCATION
1330 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515864_1330 E YOSEMITE_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
486
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> Elite IV Contractors <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑ Sump Manufacturer X Industry Standard ❑Professional Engineer <br /> ❑Other(Specif,�) <br /> Test Method Used: 0 Pressure ❑Vacuum X Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Caldwell Tester Equipment Resolution: <br /> IN <br /> MENEM= Sump# 87 Sump# 91 Sump# Diesel Sump# <br /> Sump Diameter: 36" 36" 36" <br /> Sump Depth: 72" 73" 73" <br /> Sump Material: Glass Glass Glass <br /> Height from Tank Top to Top of 21 21 2, <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 4' 4' 4' <br /> Electrical Penetration: <br /> Condition of sump prior to testing. Good Good Good <br /> Portion of Sump Tested' <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes ❑No X NA 0 Yes ❑No X NA ❑Yes ❑No X NA ❑Yes ❑No ❑NA <br /> product and water)?; <br /> Turbine shutdown response time <br /> Is system programmed for fail-safe 0 Yes 0 No X NA []Yes ❑No X NA 0 Yes []No X NA ❑Yes ❑No ❑NA <br /> shutdown?" <br /> Was fail-safe verified to be ❑Yes ❑No X NA ❑Yes ❑No X NA 0 Yes ❑No X NA 0 Yes 0 No ❑NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 MIN 15 MIN 15 MIN <br /> test: <br /> Test Start Time: 100 100 100 <br /> Initial Reading(Rj): <br /> Test End Time: 200 200 200 <br /> Final Reading(RF): PASS PASS PASS <br /> Test Duration. 1 HR I HR 1 HR <br /> Change in Reading(RF-Ri): 0 0 0 <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: 0 Pass 0 Fail ❑ Pass ❑Fail ❑ Pass ❑Fail © Pass ❑Fail <br /> Was sensor removed for testing? X Yes ❑No ❑NA X Yes ❑No ❑NA X Yes ❑No 0 NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and X Yes ❑No ❑NA X Yes ❑No 0 NA X Yes ❑No ❑NA 0 Yes ❑No ❑NA <br /> verified functional after testing?. <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Caldwell tester used measures any water drop by moving offline set by tester <br /> r a. <br /> n <br /> L TH <br /> ' if the entire depth of the sump is not tested, specify how much was tested. If the answer to agy of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.