My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1330
>
2300 - Underground Storage Tank Program
>
PR0515864
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 10:44:40 AM
Creation date
6/3/2020 10:00:02 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0515864
PE
2361
FACILITY_ID
FA0012355
FACILITY_NAME
A&A GAS FOOD MART
STREET_NUMBER
1330
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120053
CURRENT_STATUS
01
SITE_LOCATION
1330 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515864_1330 E YOSEMITE_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
486
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for GAS DEPOT #2 as of May 06, 2017. <br /> Open violations from December 29, 2016 inspection <br /> Violation #103 -Current financial responsibility documents not submitted. <br /> Financial responsibility documents have not been submitted to the EHD. The most recent financial responsibility <br /> documents submitted on CERS are dated June and December 2014. New financial responsibility documents for <br /> 2016 were found on site, but had not yet been fully completed. Current financial responsibility documents are <br /> required to be submitted annually. Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calepa.ca.gov/, and upload the required documents. <br /> Violation#105-Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. The 87 monitoring plan incorrectly lists a fill <br /> sump sensor; this sensor was removed during a previous inspection. The monitoring plans for all three tanks list all <br /> UDC sensors as 322 sensors. The sensor in UDC 9/10 is a 208. The monitoring plan must be uploaded to the <br /> California Environmental Reporting System (CERS). Immediately log into CERS, make the necessary changes, <br /> and submit for review by the EHD. <br /> Violation #107-Plot plan/site map not submitted or failed to completely show where monitoring is <br /> performed. <br /> An accurate UST Monitoring Site Plan was not submitted. The site map incorrectly includes a sensor in the 87 fill <br /> sump. A site plan must be submitted identifying the accurate locations where monitoring will be performed. <br /> Immediately log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/and upload <br /> a revised copy of the UST Monitoring Site Plan. <br /> Violation#110-Failed to submit secondary containment test report within 30 days. <br /> Secondary containment testing was scheduled to be performed on January 29, 2015. A test report has not been <br /> submitted to the EHD or the California Environmental Reporting System (CERS). A copy of the test report must be <br /> submitted within 30 days of the test. Secondary containment testing is now 25 months past due. Immediately <br /> submit a copy of the test report to the EHD or schedule this test and provide 48 hours notification to the EHD. <br /> Violation#115-Failed to inform the EHD of designated operator identification or change within 30 days. <br /> A new designated operator(Affordatest)was hired in November 2015 and notification was not provided to the EHD <br /> within 30 days of the change. Any changes shall be reported to the EHD within 30 days. Immediately log into the <br /> California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov and upload the notification <br /> identifying all the designated operators for this facility. <br /> Violation #121 -Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on December 30, 2015 and an inspection report was issued identifying information to <br /> be submitted to bring this site into compliance. This information was required to be submitted by February 4, 2016. <br /> This information has not been received resulting in a non-compliant status for this facility. The outstanding <br /> violations include: <br /> -Monitoring and response plans not current or approved by the EHD. <br /> -Failed to submit secondary containment test report within 30 days. <br /> -Failed to inform the EHD of a change in designated operator within 30 days. <br /> -Current monitoring plan approved by the EHD not found on site. <br /> An operator that receives an inspection report shall have 30 days to submit a written response that includes a <br /> statement documenting corrective actions taken or proposing corrective actions which will be taken. Ensure that a <br /> written response documenting corrective actions taken or proposed is submitted within 30 days of receiving an <br /> inspection report. <br /> Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.