Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s�gov.org/ehd — <br />ng <br />1 �'S k <br />�'� � Storage, �V, <br />-a IYR ... . tf'w'}� <br />l SRIF ih01 <br /><.. ... .. w. ,, .. _. <br />Facility Name: Facility Address: Date: <br />GAS DEPOT #2 1330 E YOSEMITE AVE, MANTECA December 30, 2015 <br />d <br />HENRMRY <br />.. .♦ 17 4; 'YRAW <br />Y <br />on 04 <br />;} <br />' -..s N'}i� <br />Item # I Remarks <br />323 <br />CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br />The 87 octane VMI line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of <br />detecting a 3 -gallon per hour leak at 10 psi. The service technician adjusted the leak detector, retested it, and it <br />passed. This was corrected on site. <br />This is a Class II violation. <br />325 <br />CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons. <br />The diesel spill container failed when tested. All spill containers shall have a minimum capacity of five gallons and <br />be capable of containing a spill or overfill until it is detected or cleaned up. The technician tightened the fill adapter, <br />and retested this spill container with passing results. This was corrected on site. <br />This is a repeat violation, Class II. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, 30 days from receipt of the <br />full inspection report. A checklist only was left onsite at the time of inspection. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />Note: The ball float cap was removed and the ball float was observed inside the 91 -octane vapor container, the <br />ball float cap could not be opened for observation on the 87 -octane UST. Ensure that ball float functionality <br />could be verified during future inspections. <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br />THIS FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received By t <br />� <br />Received By (printed name and title): <br />Kevin Hur, Operator <br />Date: <br />(signature): vtQ �. rnu, �A <br />Inspector <br />Inspector (printed name and title): <br />Inspector Phone: <br />(signature):rv_lk�ELENA <br />MANZO, Senior REHS <br />(209) 953-7699 <br />rage a or 0 <br />