ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0515864
PE
2361
FACILITY_ID
FA0012355
FACILITY_NAME
A&A GAS FOOD MART
STREET_NUMBER
1330
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120053
CURRENT_STATUS
01
SITE_LOCATION
1330 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515864_1330 E YOSEMITE_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
486
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
77 <br />UNIFIED PROGRAM CONSOLIDATED FORM <br />UNDERGROUND STORAGE TANK <br />MONITORING PLAN - (Page 2 of 2 <br />VL UNDER DISPENSER CONTAINMENT (UDC) MONITORING (Ch � l ) <br />UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) <br />g 1. CONTINUOUS ELECTRONIC MONITORING ❑ 2. FLOAT AND CHAIN ASSEMBLY ❑ 3. ELECTRONIC STAND-ALONE <br />49o -54a. <br />❑ 4. NO DISPENSERS ❑ 99.OT14ER (Specify) <br />490-546• <br />LEAK MONITOR MANUFACTURER: Veeder Root 490-55. MODEL #: TLS -350 <br />490-56. <br />LEAK SENSOR MANUFACTURER: Veeder Root 490-17' MODEL #(S): 794380-322 <br />490-59. <br />DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. ® a YES ❑ b. NO <br />490 -59 - <br />UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN. g a YES ❑ b. NO <br />490-60- <br />FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. g a. YES ❑ b. NO <br />490-61• <br />UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. ❑ a. YES g b- NO <br />490-62. <br />UDC CONSTRUCTION IS: g 1. SINGLE WALL ❑ 2. DOUBLE WALL <br />490.63• <br />IF DOUBLE WALL: <br />UDC INTERSTITIAL SPACE IS MONITORED BY: ❑ a. LIQUID ❑ b- PRESSURE ❑ c- VACUUM <br />490-640-. <br />A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. ® a. YES ❑ b. NO <br />490-646• <br />' VII. PERIODIC SYSTEM. TESTING , <br />. <br />❑ 1. ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED <br />490-65. <br />LEAK DETECTION (FEDI MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED. I23 ccit §2644.1' <br />Q <br />g 2. SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. <br />0-9° 66. <br />® 3. SPILL BUCKETS ARE TESTED ANNUALLY. <br />490-67• <br />VIII. RECORD KEEPING <br />The following monitoring/maintenance records are kept for this fhcility: <br />a` <br />ga. ALARM LOGS ❑ b. VISUAL INSPECTION RECORDS ❑ c- TANK INTEGRITY TESTING RESULTS <br />❑ d. SIR TESTING RESULTS (and supporting documentation records) ❑ e. TANK GAUGING RESULTS (and supporting documentation records) <br />❑ £ ATG TESTING RESULTS (and supporting documentation records) ❑ g. CORROSION PROTECTION 60 -DAY LOGS <br />g h. EQUIPMENT MAINTENANCE AND CALIBRATION RECORDS <br />G . <br />Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to their job duties: <br />490-69a. <br />REFERENCE DOCUMENTS MAINTAINED AT FACILITY (Check all that apply) <br />g THIS UNDERGROUND STORAGE TANK MONITORING PLAN (Required) <br />490-69b• <br />® OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT (Required) <br />490.69c. <br />❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br />490-W. <br />❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW <br />49o -69e. <br />❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br />490-69f. <br />STATISTICAL INVENTORY RECONCILIATION" <br />490-69g. <br />❑ SWRCB PUBLICATION: "UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS" <br />❑ OTHER (Specify): <br />490-696. <br />490-69i. <br />This facility has a "Designated UST Operator" who has passed the California UST System Operator Exam administered by the International Code Council <br />490-70. <br />(ICC). The "Designated UST Operator" will train facility employees in the proper operation and maintenance of the UST systems annually, and within 30 <br />days of hire. This training will include, but is not limited to, the following: <br />➢ Operation of the UST systems in a maturer consistent with the facility's best management practices. <br />➢ The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan. <br />➢ The facility employee's role with regard to spills and overfills as specified in the facility's UST Response Plan. <br />➢ Name(s) of contact person(s) for emergencies and monitoring alarms. <br />X. +CO�VIMENT IADDITIQNAL V"RMATION <br />Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan. <br />490-71• <br />T-1 87 and T-2 91 have overfill flappers set at 95%, T-3 Diesel has a ball float with straight tube set at 90%. <br />XU PERSONNEL RESPONSIBILITIES . <br />The UST Owner/Operator is responsible for ensuring that 1.) the daily/routine UST monitoring activities and maintenance of UST leak detection equipment <br />covered <br />by this plan occurs; 2.) all conditions that indicate a possible release are investigated; and 3. all monitoring records are maintained properly. <br />v <br />THE FOLLOWING PERSON(S) ARE RESPONSIBLE FOR PERFORMING THE MONITORING AND EQUIPMENT MAINTENANCE: <br />NAME: Kevin Hur 490-72- TITLE:Owner/Operator <br />490-73• <br />NAME: 490-74. TITLE: <br />490-75. <br />The Designated UST Operator shall perform a monthly visual inspection of the facility, provide a report to the owner/operator, and inform the owner/operator of any <br />conditions that need follow action. <br />XII. QVVNER/®PERAT®R :SI�iNATURE;: <br />CERTIFICATION: I certify that the information provided herein is true and accurate to the best of my knowledge. <br />APPLICANT SIGNATURE <br />DATE: <br />490-77• <br />REPRESI^ MNG: 0 1. Tads ❑ 2. FaT ❑ 3_ Avt d w of Owm 490-76. <br />a90 -7s' <br />490-79• <br />APPLICANT NAME (print): <br />APPLICANT TITLE: <br />Kevin Hur <br />UPCF UST -D (12/2007) - 3/4 www.unidoes.org <br />