My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3304
>
2300 - Underground Storage Tank Program
>
PR0516354
>
COMPLIANCE INFO_2002-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 11:44:26 AM
Creation date
6/3/2020 10:00:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2007
RECORD_ID
PR0516354
PE
2361
FACILITY_ID
FA0012437
FACILITY_NAME
CHEVRON 352324
STREET_NUMBER
3304
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
07120013
CURRENT_STATUS
01
SITE_LOCATION
3304 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0516354_3304 W HAMMER_2002-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NEW UST INSTALLATION INSPECTION RECORD 40 <br />A I <br />P N ALL TANKS TO BE INSTALLED AND TESTED IN ACCORDANCE <br />P I WITH MANUFACTURER WRITTEN SPECIFICATIONS <br />R T <br />0 I <br />V A <br />E L <br />a S <br />4 I ITEM OR EWIPMENT INSPECT® <br />DATE j <br />FINAL INSPECTION <br />13. <br />' <br />6. PRIMARY PIPING TEST (MINIMUM 40 PSI/30 HIM) (CCR 2636 (e)) <br />i. UST PLANS ITTED/ FEES PAID (H¢S CODE 25287) <br />PERFORMANCE TEST OF CONTINUOUS MONITORING SYSTEM (PANEL) <br />7. SECONDARY PINING CONTAINMENT TEST Pal: HRS'/MIN: . CCCR 2636 (e)) <br />15.PERFORMANCE <br />Z. UST INSTALLATION PLANS APPROVED <br />INITIAL INSPECTIONS <br />i 3. INSPECTION AND TEST OF SECONDARY CONTAINMENT: HOLIDAY: <br />VA . PSI: HRS/MIN: BRINECLIOUID ANNULAR): OTHER: <br />PERFORMANCE TEST OF AUTOMATIC PUMP SYSTEM SHUT-OFF <br />4. UNUSED TANK OPENINGS SEALED AND CORROSION PROTECTED PEI <br />17. <br />4. PRIMARY TANK TEST: PSI: HRS/MIN: <br />5. TANK APPROPRIATELY PLACED WITH APPROVED BACKFILL (APIIPEI) <br />PIPING INSPECTIONS <br />FINAL INSPECTION <br />13. <br />PERFORMANCE TEST FOR "ALL"MONITORING' PROBES <br />6. PRIMARY PIPING TEST (MINIMUM 40 PSI/30 HIM) (CCR 2636 (e)) <br />14. <br />PERFORMANCE TEST OF CONTINUOUS MONITORING SYSTEM (PANEL) <br />7. SECONDARY PINING CONTAINMENT TEST Pal: HRS'/MIN: . CCCR 2636 (e)) <br />15.PERFORMANCE <br />TEST OF LINE LEAK DETECTION <br />N%. LAKE TEST ON ALL. SLIKPS (24 HR_ MINI ) HRS-* (CCR 2635 (a) (4)) <br />16. <br />PERFORMANCE TEST OF AUTOMATIC PUMP SYSTEM SHUT-OFF <br />4. UNUSED TANK OPENINGS SEALED AND CORROSION PROTECTED PEI <br />17. <br />BALL FLOAT VALVES INSTALLED <br />f IO. OVERSPILL PERFORMANCE TEST (CCR 2635 (b) (1) (C)) <br />18. <br />OVERFILL PROTECTION IHST /APPR <br />11. ALL PIPING AND FITTINGS CORROSION PROTECTED (CCR 2636 (b)) <br />14. <br />TANK ACCESS PORTS BROUGHT TO GRADE t AND WATERTIGHT) <br />12. PIPING SLOPES TO COLLECTION {CC:�I 2636 tc)C1)) <br />FINAL INSPECTION <br />13. <br />PERFORMANCE TEST FOR "ALL"MONITORING' PROBES <br />(CCR 2632 (c) (2)) <br />14. <br />PERFORMANCE TEST OF CONTINUOUS MONITORING SYSTEM (PANEL) <br />(CCR 2632 (c) (2)) <br />15.PERFORMANCE <br />TEST OF LINE LEAK DETECTION <br />(= 2643 Cc) t1)) <br />16. <br />PERFORMANCE TEST OF AUTOMATIC PUMP SYSTEM SHUT-OFF <br />(CCR 2636 ($)) <br />17. <br />BALL FLOAT VALVES INSTALLED <br />18. <br />OVERFILL PROTECTION IHST /APPR <br />(CCR 2635 (b) (2)) <br />14. <br />TANK ACCESS PORTS BROUGHT TO GRADE t AND WATERTIGHT) <br />API <br />20. <br />TANK INTEGRITY TEST (PASSING COPY) <br />(CCR 2635 Ca) (5)) <br />21. <br />MONITORING PLAN, RESPONSE PLAN AM LOG SOOK ON SITE <br />(CCR 2632 (d)) <br />22. <br />OLN FORM COMPLUM AND MMITTED <br />(CCR 2635 (d)) <br />23. <br />$24. <br />MONITORING METHOD FOR ALL TANKS AND PIPING APPROVED <br />ALL CONDITIONS NET; FACILITY PERMIT ISSUED <br />(CCR 2630-ZO6) <br />CH+S CODE 25284) <br />COMMENTS: <br />
The URL can be used to link to this page
Your browser does not support the video tag.