My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3304
>
2300 - Underground Storage Tank Program
>
PR0516354
>
COMPLIANCE INFO_2002-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 11:44:26 AM
Creation date
6/3/2020 10:00:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2007
RECORD_ID
PR0516354
PE
2361
FACILITY_ID
FA0012437
FACILITY_NAME
CHEVRON 352324
STREET_NUMBER
3304
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
07120013
CURRENT_STATUS
01
SITE_LOCATION
3304 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0516354_3304 W HAMMER_2002-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Atrg 25 00 11:46a St -eve Schamaun 91 -366-8631 p.5 <br />40 4 <br />)ST SYSTEM DRAWING INFORMATION <br />1. T(rree complete sets of plans (include manufacturer's specification sheets for proposed equipment to be installed). <br />2. Plans drawn to Seale in non-eresabie print. <br />3. Plot plan to show location of tanks and all associated piping. <br />4. X Striker plates or drop tube -mounted bottom protectors illustrated below all accessible openings. <br />5. ^ Tank crass-sectiorrut diagram. <br />6• Detail of tank, associated piping, excavation and cover. <br />7. �( Tank(s) and piping approved by a nationally recognized independent testing organization. (Title 23, Chapter 16, <br />Article 3, section 2631 (b) & 26351 <br />8. Verification of product compatibility with the tank(s), piping, monitoring <br />i <br />device(s), epoxy or silicone glues, etc. <br />i <br />Manufacturer's written installation instructions for tank(s), piping, monitoring devices, etc. <br />10. At the installation site, prior to installation, a tightness test shall be performed on both primary (1) and <br />secondary (2°) containment systems before covering. (Section 2635 (a) (3) 9 (4)1 <br />11. Tank integrity test required upon completion of installation with tank in operating condition. Test results to be <br />submitted directly to PNS-EHD from the testing company or owner of facility. (Health & Safety Code, Division 20, <br />Chapter 6.7, Section 25291 (h)] <br />12_ Jaur rue rrrrue <br />13. <br />1 <br />it <br />TANK(s) To BE INSTALLED <br />.0 A. Steet-ctad with fiberglass reinfvreed plastic coatings, composites, or equivalent non-metallic exterior <br />coatings or coverings. <br />0 ) Tested at the installation si-te using an electric resistance holiday detector. <br />(2) Vacuum applied to interstitial space. <br />,r„•"_ 8. Fiberglass <br />(1) Installation instructions require an air test and soapbubbte"test prior to installation. <br />(2) Vacuum applied to interstitial space. <br />— (3) Hydrostatic annular (primary tank pressure test). <br />C. Hon -clad steel tank (Section 2635 (a) (2) (A)J <br />(1) Cathodic protection provided for entire tank, Piping and camponents (nuts, Botts, washers, <br />etc.). <br />____ (2) Field installed cathodic protection"'systems"designed and certified as adequate by a <br />corrosion specialist. <br />(3) Impressed current systems to be inspected no less then every 60 days. <br />
The URL can be used to link to this page
Your browser does not support the video tag.