My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0013392
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
O
>
120 (STATE ROUTE 120)
>
12522
>
2600 - Land Use Program
>
GX-91-2
>
SU0013392
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 4:01:46 PM
Creation date
6/4/2020 1:22:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0013392
PE
2600
FACILITY_NAME
GX-91-2
STREET_NUMBER
12522
Direction
E
STREET_NAME
STATE ROUTE 120
City
MANTECA
Zip
95336-
APN
24335002
ENTERED_DATE
6/2/2020 12:00:00 AM
SITE_LOCATION
12522 E HWY 120
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> 141706 <br /> NOTES 31 . APPLICANT SHALL PROVIDE AN APPROVED POTABLE WATER } <br /> 1 . THE ASSESSORS PARCEL NUMBERS FOR THIS SITE ARE: SUPPLY FOR ALL EMPLOYEES . <br /> am <br /> 243-350-02 & 243-350-17 32 . APPLICANT SHALL PROVIDE APPROVED SANITARY FACILITIES <br /> FOR ALL EMPLOYEES . m <br /> 2 . THIS PROJECT SITE CONTAINS 190 . 08 ACRES ± <br /> 33 . THE APPLICANT SHALL IMPLEMENT THE AIR POLLUTION CONTROL <br /> 3 . THE AVERAGE EXISTING ELEVATION OF THE PROJECT SITE IS DISTRICT' S FUGITIVE DUST CONTROL GUIDELINES DURING <br /> 53 . 2 • EXCAVATION. <br /> 4 . THE AVERAGE SURROUNDING ELEVATION OF THE PROJECT SITE 34 . ALL INTERNAL COMBUSTION ENGINES ON EXCAVATION VEHICLES <br /> IS 52 . 0 . SHALL BE PROPERLY TUNED AND MAINTAINED. o <br /> LO <br /> 5 . THE AVERAGE FINISHED GRADE ELEVATION OF THE PROJECT 35 , ALL PRIVATE ROADS INVOLVED IN THIS EXCAVATION SHALL BE <br /> SITE IS 52 . 0 . MAINTAINED SO AS TO CONTROL THE CREATION OF DUST. <br /> 6 . THIS PROPOSED GRADING EXCAVATION PROPOSES TO REMOVE 36 . CUTS OR EXCAVATIONS WILL NOT BE ALLOWED WITHIN 10-FEET <br /> APPROXIMATELY 333 , 700 CUBIC YARDS OF MATERIAL. OF ANY POWER POLE . <br /> 7 . EXISTING GROUND WATER IS BELOW ELEVATION 32 . 37 . NO FILLS SHALL BE ALLOWED THAT WOULD IMPAIR POWER POLE <br /> 8 . NO STRUCTURES ARE TO BE REMOVED AS A PART OF THIS GROUND-Tp-CONDUCTOR CLEARANCES , <br /> w <br /> 0 <br /> PROJECT. 38 . ANY NIGHT LIGHTING ESTABLISHED ON THE PROPERTY SHALL BE <br /> ARRANGED AND CONTROLLED TO NOT ILLUMINATE PUBLIC <br /> 9 . THE EXCAVATION SITE IS NOT SUBJECT TO A 100 YEAR RIGHTS-OF-WAY OR ADJACENT PROPER'T'IES . <br /> FLOOD . <br /> 39 . BENCH MART{ : C & G. S . BRASS DISC AT CALLA DRIVE, D-958 <br /> 10 . A PERFORMANCE BOND OR OTHER FINANCIAL SECURITY ELEVATION = 49 . 53 . <br /> SUFFICIENT TO COVER THE COST OF REHABILITATION OF THE SITE <br /> FOR AGRICULTURAL USE SHALL BE SECURED BY THE OWNER OR <br /> CONTRACTOR, AND APPROVED BY COUNTY COUNSEL, PRIOR TO THE <br /> COMMENCEMENT OF ANY EXCAVATION . IrZ <br /> 11 . THE OWNER AND CONTRACTOR SHALL CONFORM TO ALL GENERAL <br /> AND SPECIAL CONDITIONS OF APPROVAL SET BY THE SAN <br /> JOAQUIN COUNTY PLANNING DEPARTMENT AND DEPARTMENT OF <br /> Z LL <br /> PUBLIC WORKS . <br /> o_ <br /> 12 . THE OWNER AND CONTRACTOR SHALL CONFORM TO ALL SAN <br /> JOAQUIN COUNTY ENVIRONMENTAL HEALTH STANDARD EXCAVATION (� <br /> • CONDITIONS . n <br /> ■ <br /> 13 . THE CONTRACTOR SHALL MAINTAIN A WATER TRUCK ON THE > Im >- <br /> SITE TO PROVIDE DUST CON'T'ROL AS NECESSARY . <br /> PROJECT � ■ i"_ <br /> 14 . SOUTH SAN JOAQUIN IRRIGATION DISTRICT SHALL BE NOTIFIED Im <br /> OF ANY Z <br /> AT LEAST 48 HOURS IN ADVANCE OF THE COMMENCEMENT <br /> EXCAVATION WORK. W LL <br /> O <br /> 15 . THE S . S .J . I . D . FACILITIES SHOWN HEREON ARE PLOTTED FROM ( � <br /> AVAILABLE RECORDS AND SURFACE LOCATION TO SHOW GENERAL v <br /> LOCATION ONLY . THE CONTRACTOR SHALL BE RESPONSIBLE FOR <br /> DETERMINING THE ACTUAL LOCATION OF ALL FACILITIES PRIOR z z <br /> TO EXCAVATION . <br /> 16 . THE LAND OWNER AND EXCAVATION CONTRACTOR AGREE NOT TO Q <br /> PERFORM ANY EXCAVATION OF GRADING WITHIN THE S . S . J . I .D. 0 <br /> EASEMENT OR WITHIN 15 FEET OF THE CENTERLINE OF THE <br /> PIPELINE , WHICHEVER IS GREATER. <br /> 0 <br /> 17 . EXCAVATIONS ADJACENT TO A DISTRICT PIPELINE AND/OR <br /> CANAL SHALL HAVE A MINIMUM 3 : 1 SLOPE FROM EXCAVATED <br /> FIELD TO TOP OF BERM. <br /> Z <br /> 18 . THE LAND OWNER/EXCAVATION CONTRACTOR WILL "TPKE' SUCH <br /> STEPS AS REQUIRED BY THE S . S . J . T . D. WATER <br /> SUPERINTENDENT TO REMEDY EROSION ON BANKS ADJACENT TO <br /> THE DISTRICT ' S FACILITIES . <br /> 19 . NO SOIL WILL BE STOCK PILED OVER THE S . S .J, I . D. <br /> PIPELINE . <br /> 20 . NO HEAVY EQUIPMENT WILL TRAVEL OVER THE S . S .J . I . D . <br /> OWNER <br /> PIPELINE AND/OR CANAL WITHOUT APPROVED BRIDGING, SAID <br /> BRIDGING TO BE APPROVED BETWEEN S . S .J . I . D. AND THE <br /> . FARMS <br /> 120B1E. HIGHWAY 120 <br /> CONTRACTOR. MANTECA, CA 95336 a CrJ <br /> 21 , NO TREES AND/OR RUBBISH WILL BE DISPOSED OF OR STORED <br /> ON THE S . S .J . I . D. EASEMENT OR FACILITIES . z <br /> 22 . THE LAND OWNER AND EXCAVATION CONTRACTOR AGREE THAT THE <br /> EXISTING PIPELINES DO NOT PRESENTLY LEAK AND AGREE THAT DATE <br /> ANY DAMAGE WILL BE REPAIRED AT THE LAND OWNER' S <br /> " <br /> EXPENSE. r t ] U <br /> 23 . IT IS UNDERSTOOD BY THE LANDOWNER AND THE EXCAVATION pAT �I ^ <br /> CONTRACTOR THAT THE S . S .J . I .D . SHALL NOT BE HELD W <br /> TO REMEDY HIGH WATER TABLE PROBLEMS IF THEY <br /> RESPONSIBLE <br /> OCCUR DUE TO THIS PROPOSED EXCAVATION. <br /> DATE <br /> 24 . IT IS THE CONTRACTOR' S RESPONSIBILITY TO VERIFY THE <br /> LOCATION OF ALL EXISTING UTILITIES . THE UTILITIES <br /> SHOWN HEREON ARE PLOTTED FROM AVAILABLE RECORDS AND <br /> SURFACE LOCATION TO SHOW GENERAL LOCATION ONLY . THE V <br /> CONTRACTOR SHALL DO NO EXCAVATION UNTIL ALL UTILITY W <br /> AGENCIES HAVE BEEN NOTIFIED AND HAVE BEEN GIVEN THE <br /> OPPORTUNITY TO MARK THEIR UNDERGROUND FACILITIES IN THE <br /> FIELD , THE CONTRACTOR SHALL TAKE ALL NECESSARY ~ ~ <br /> PRECAUTIONARY MEASURES TO PROTECT ALL UTILITIES . <br /> . R . <br /> • v Louise: Av O u U <br /> 25 . THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE <br /> RESPONSIBILITY FOR J08SITE CONDITIONS THROUGHOUT THE <br /> COURSE OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS Jeane Rd. �` a 9 <br /> AND PROPERTY AND COMPLIANCE WITH ALL HEALTH ,Q Conic ex Rd. � <br /> REQUIREMENTS . THIS CONDITION SHALL APPLY CONTINUALLY 120 <br /> AND NOT BE LIMITED TO NORMAL WORKING HOURS . THEE ,^ <br /> CONTRACTOR SHALL INDEMNIFY AND HOLD HARMLESS THE OWNER _ CALLA Leroy Vf <br /> AND THE SURVEYOR FROM ANY AND ALL LIABILITY, REAL OR offal A9 5Ct10o� 51 Rd. Donahoe <br /> ALLEGED , IN CONNECTION WITH THE PERFORMANCE OF WORK ON �� 7 Ave. <br /> THIS PROJECT EXCEPTING FOR LIABILITY ARISING FROM THE Graves Rd. - - o A <br /> a <br /> Rd <br /> SOLE NEGLIGENCE OF THE OWNER OR SURVEYOR. <br /> Y . Q <br /> y 9 O Mello 'Q O <br /> 26 . THE QUANTITIES SHOWN HEREON ARE APPROXIMATE AND FOR a <br /> PURPOSES OF THIS PERMIT ONLY . THE CONTRACTOR AND/OR I; s� > South <br /> Clinton <br /> rl <br /> o <br /> �' s r Q S <br /> OWNER SHALL NOT USE THIS GRADING EXCAVATION PERMIT AS A <br /> BASIS OF PAYMENT FOR EXCAVATED MATERIAL. River Rd. <br /> Sedan Rd. <br /> O autos <br /> 27 . STOCKPILING WILL NOT BE REQUIRED . A SOILS REPORT IS Veritas c Colo <br /> ? ,� Z <br /> BEING PREPARED AND WILL BE AVAILABLE BEFORE THE <br /> v ? icy O Milgeo Ave_ SP <br /> ISSUANCE OF A PERMIT . <br /> 28 . ANY PRIVATE OR DISTRICT IRRIGATION STRUCTURE INSTALLA•- Q dR1 P q N ± T! <br /> v S� <br /> TION OR MODIFICATION NECESSITATED BY THE PROPOSED WBSt Ripon R = 3 0 <br /> EXCAVATION SHALL BE PERFORMED AT THE OWNER' S EXPENSE . Drr <br /> ATE <br /> FURTHER, OWNER SHALL OBTAIN A "STRUCTURE APPLICATION p ~ <br /> C Lyon" (U '^ p -]C DRAWN BY: <br /> AND AGREEMENT" APPROVAL FROM THE DISTRICT ' S BOARD O} _aMEYOR ' SLATEMENT Y Hutchinson .��4 c'` o <br /> DIRECTORS PRIOR TO INSTALLING, MODIFYING OR REMOVING <br /> ANY IRRIGATION STRUCTURES ON DISTRICT FACILITIES . I , MICHAEL L , QUARTAROLI , HEREBY STATE THAT I ••Afl A LICENSED Q fpr CHECKED BY <br /> LAUD SURVEYOR NO , 4450 OF THE STATE OF CALIFORNIA AND THAT S . S .J , I . D. , TTS EMPLOYEES AND AGENTS ARE NOT RESPONSIBLE FOR N16?. <br /> 29 . NO EXCAVATION IS PERMITTED INTO THE GROUND WATER TABLE THIS EMAP CORRECTLY R PR SEhJ S A TOPOGRAPHIC SURVEY MADE UN- VERIFICATION OF THE ELEVATIONS AND DIMENSIONS INDICATIED ON JOB NO. <br /> WITHOUT SPECIFIC APPROVAL FROM THE REGIONAL WATER -DER MY DIRECTION ONl fi _ i �°� PLANS NOR ANY ERRORS OR OMISSIONS THAT MAY BE PRESENT . 61P- 11-1 <br /> QUALITY CONTROL BOARD, CENTRAL VALLEY REGION. APPROVAL IS SUBJECT TO THE DATA SHOWN WHICH APPEARS T(O BE IN SHEET <br /> CONFORMITY WITH S . S .J . I . D. REQUIREMENTS FOR PROTECTIOIN OF <br /> 30 . THE MATERIALS FROM THIS EXCAVATION SHALL NOT BE t � 9/ DISTRICT FACILITIES . VICINITY MAP 1 <br /> DEPOSITED INTO ANY WATER COURSE NOR IN ANY WAY <br /> CONTRIBUTE TO THE POLLUTION THEREOF. MI WEL L QUARTAROL 11, L . S . 4450 A SO CONDITIONALLY APPROVED DATE G- of 4 SHEETS <br />
The URL can be used to link to this page
Your browser does not support the video tag.