My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TOSTE
>
2450
>
3500 - Local Oversight Program
>
PR0545734
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2020 1:20:26 PM
Creation date
6/4/2020 2:57:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
WORK PLANS
RECORD_ID
PR0545734
PE
3528
FACILITY_ID
FA0010191
FACILITY_NAME
TRACY-PONTIAC-CADILLAC-GMC TRUCK
STREET_NUMBER
2450
STREET_NAME
TOSTE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
238020-06
CURRENT_STATUS
02
SITE_LOCATION
2450 TOSTE RD
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
176
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' 18 July 2002 <br /> AGE-NC Project No 96-0254 <br /> ' Page 4 of 17 <br /> ' were as high as 550 mg/kg(B4-9') TPH-g was not detected at depths of 12 to 16 feet in the <br /> area of the former USTs,nor was TPH-g detected in the soil sample collected from B6 Total <br /> petroleum hydrocarbons quantified as diesel (TPH-d) was detected in the soil sample <br /> ' collected from probe boring B2 at a depth of 8 feet bsg at a concentration of 510 mg/kg <br /> • BTEX compounds were detected in soil samples collected from depths of less than 8 feet bsg <br /> at concentrations ranging from 0 007 (ethyl benzene, B6-8') to 480 mg/kg(xylene, B5-6') <br /> ' BTEX compounds were also detected at a depth of 12 feet bsg in borings B2,B3 and B5 No <br /> petroleum hydrocarbons or BTEX compounds were detected in the soil sample collected <br /> from a depth of 16 feet bsg in the former UST area Laboratory results of soil samples <br /> fanalyzed for petroleum hydrocarbons area summarized in Table 2 <br /> • TPH-g was detected in each of the eight grab ground water samples collected from the site <br /> ' at concentrations ranging from 220 micrograms per liter(µg/1)to 240,000 µg/1 TPH-d was <br /> detected in both of the grab ground water samples at concentrations of 44,000 µg/1 and <br /> 310,000 µg/1 BTEX compounds were detected in each of the water samples analyzed at <br /> ' concentrations ranging from 0 56 µg/1 benzene in boring B1 to 20,000 µg/1 of benzene in <br /> boring B7 MTBE was also detected at concentrations up to 1,000 µg/1 by EPA Method <br /> 8020 However,the highest concentration of MTBE detected by EPA Method 8260 was 180 <br /> '• gg/l Laboratory results of grab ground water samples analyzed for petroleum hydrocarbons <br /> are summarized in Table 3 <br /> ' On 12 and 13 February 1998 five ground water monitoring wells were installed on-site and off-site <br /> of the subject property Soil borings B10 and B14 were completed as dual-screened ground water <br /> ' monitoring wells MW-2 and MW-1,respectively Soil borings B11,B12,and B13 were completed <br /> as conventional ground water monitoring wells MW-3, MW-6 and MW-5, respectively <br /> ' TPH-g was detected in samples collected from well MW-1A and MW-1 B at concentrations <br /> of 220 and 2,000µg/I,respectively TPH-d was detected samples collected from well MW-1B <br /> at a concentration 160µg/I Benzene was detected in samples collected from wells MW-lA <br /> ' and MW-1B at concentrations of 15 lig/t and 530µg/1,respectively Toluene,ethyl benzene <br /> and xylenes were also detected in MW-i A and MW-1B at concentration as high as 260 µg/1 <br /> (toluene, MW-1B) MTBE was detected in the sample collected from well MW-1B at a <br /> concentration 9 9 µg/1 Laboratory results of soil samples analyzed for petroleum <br /> hydrocarbons area summarized in Table 2 <br /> ' On 04 November 1999, six soil probe borings(PBI through PB6)were advanced at the site under <br /> EHD oversight Probe borings were advanced in the area of the former USTs, dispenser and <br /> I northwest to the property line, a total of 11 soil samples were subnutted for analysis In addition, <br /> grab ground water samples were collected from borings PB-1,PB-4 and PB-5 and were submitted <br /> • for analysis <br /> ' Advanced GeoEnwroumen[al,Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.