ARCHIVED REPORTS_XR0007330
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
15406
>
3500 - Local Oversight Program
>
PR0545741
>
ARCHIVED REPORTS_XR0007330
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/8/2020 12:51:42 PM
Creation date
6/8/2020 12:34:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0007330
RECORD_ID
PR0545741
PE
3528
FACILITY_ID
FA0006284
FACILITY_NAME
YAMADA BROS INC
STREET_NUMBER
15406
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
18917007
CURRENT_STATUS
02
SITE_LOCATION
15406 S TRACY BLVD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Quarterly Report - Fourth Quarter 2003 and First Quarter 2004 <br /> YAMADA BROTHERS <br /> 15406 South Tracy Boulevard, Stockton, California <br />' 1.0. INTRODUCTION <br /> In accordance with the request of Mr Bob Yamada of Yamada Brothers, Inc , Advanced <br />' GeoEnvironmental, Inc (AGE)has prepared this quarterly report for the property located at 15406 <br /> South Tracy Boulevard, Stockton, California (site) The scope of work included quarterly ground <br />' water monitoring, purge-water disposal, and resurveying of monitoring wells The location of the <br /> site and the immediately surrounding area are illustrated on Figure 1 Structures and monitoring well <br /> locations on the site are illustrated on Figure 2 Background information is summarized in <br />' Appendix A <br />' 2.0. PROCEDURES <br /> Field work was performed in accordance with the Central Valley Regional Water Quality Control <br />' Board(RWQCB)and San Joaquin County Environmental Health Department(EHD)guidelines for <br /> investigations of underground storage tank(UST)sites and sampling ground water monitoring wells, <br /> lirespectively <br /> 2 1 QUARTERLY GROUND WATER MONITORING EVENTS <br /> AGEP ersonnel monitored and sampled monitoring wells MW-1 through MW-3 and domestic well <br /> DW-1 on 16 December 2003 and 25 March 2004 <br />' 2 1 1 Well Monitoring and Evacuation <br /> A Solinst water level meter was used to measure the depth to ground water to the nearest 0 01 foot <br />' in the three wells relative to the tops of the well casings (well heads) The ground water elevations <br /> and gradient were determined from this data (Table 1) <br />' After recording water level measurements, dedicated, disposable plastic bailers were used to purge <br /> the monitoring wells of water Approximately seven to ten gallons of water were removed from each <br /> well(approximately 3 casing-water volumes) Ground water temperature,pH and conductivity were <br />' measured at regular intervals during the purge process using an Oakton water analyzer Field data <br /> sheets are included in Appendix D Purged water was stored on site in labeled, 55-gallon DOT- <br /> approved drums <br /> I <br /> i <br /> Advanced GeoEnvironmental,Inc <br />