Laserfiche WebLink
SEF 0 4 2U2t <br /> ENVIRONMENTAL HEALTH <br /> TEST INSTRUCTIONS w-�Socket <br /> POPPET & FLOAT MOVEMENT adaptor <br /> FOR TESTABLE MODELS ONLY <br /> TOOLS NEEDED FOR TESTING: <br /> 1 . 1 /4" square drive extension or 3/8" square drive ex- <br /> tension with 3/8" to 1 /4" socket adapter. ( , <br /> 2 . Torque wrench i 1 /4" or 3/8" square drive ratchet <br /> wrench . fi� <br /> 3 . Pipe dope. �..`_�_ . <br /> ��, 1 -� <br /> Ah <br /> 4 . Flashlight (optional). Open Poppet Closed Moppet <br /> PEST STEL 1 : Test Figure 7 <br /> Remove spill container cover and fill cap from fill adapt- <br /> er and look down into the tube and make sure no debris Pull on extension and <br /> or foreign objects are present. If debris or foreign ob- socket adaptor <br /> I jects are present take appropriate steps before proceed- <br /> ing. Look down Into the tube and ensure poppet is <br /> completely protected by the deflection shield . See Test <br /> Figure 1 . If poppet is exposed and tank is not full the <br /> overfill valve should be replaced . A flashlight may help <br /> = � <br /> when inspecting the tube. <br /> TEST STEP 2: <br /> Unthread the socket adaptor assembly from the inlet ' - ` 1 <br /> tube using a 1 /4" square drive extension and wrench . <br /> The extension will attach to the socket adaptor. Secures - <br /> all tools to ensure they don't fall into the tank or valve . <br /> With the extension still attached pull on the socket ;` _ ...._ _ .. _.. ._, ._._ <br /> adaptor and cable assembly and ensure float and pop- <br /> _...... <br /> pet move / function properlye it should only require 3" � = <br /> to 4" of movement and less than 5 lbs of force In order <br /> to actuate the float and poppet. When looking down <br /> Into the upper tube ensure poppet is visible and moves Open <br /> into the flow path (see Test Figure 1 & 2) when socket Poppet Closed <br /> adaptor is pulled and resets properly when socket adap- ! Poppet j <br /> for is released . if poppet does not actuate freely take t I Float moves <br /> appropriate steps to correct, up <br /> TEST STEP 3 : <br /> Apply pipe dope to the socket adaptor threads. Pipe <br /> dope should be a non_hardening gasoline resistant pipe <br /> thread seal compound. Make sure poppet and float <br /> have reset properly and are not visible then install sock- <br /> et adaptor and torque to 3 .5 ft4bs (42 in-lbs) minimum <br /> to 5.0Mbs (60 In-lbs) maxlmum. After installing socket <br /> adaptor, to ensure vapor tightness, OPW recommends TestF1gure2 <br /> conducting pressure testing per CARE TP201 . 1 D . Some <br /> areas may requ11 <br /> ire pressure testing of overfill valve per <br /> CARE TP201 . 1 D to ensure valve is vapor tight, if the <br /> drop tube fails pressure testing it may be necessary to � <br /> check the seas at the poppet adaptor threads . Reinstall € <br /> fill cap <br /> and spill container cover after testing. R <br /> �. F 2020 17 <br /> ENVIRONMENTAL HEALTH <br />