Laserfiche WebLink
SAN J OAQ U I N Environmental Health Department <br /> OUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address: Date : <br /> Pershing Holdings , Inc . DBA Esclon Arco 1329 Escalon Ave , Escalon February 19 , 2020 <br /> UST System Observations <br /> 313 HSC 25290 . 1 , 25290 .21 Failure to construct, operate , and maintain primary containment as product-tight ❑ V ❑ R ❑ COS <br /> 25291 <br /> 314 HSC 25290. 11 25290.21 Failed to have secondary containment or secondary containment not tight ❑ V ❑ R ❑ COS <br /> 25291 <br /> 315 HSC 25291 (e) Water in secondary containment not removed , analyzed , and properly disposed of (pre-Jul 2003) ❑ V ❑ R ❑ COS <br /> 316 HSC 25290. 1 (c3), Secondary containment not constructed to prevent water intrusion (after Jul 2003) ■ V ■ R in COS <br /> 25290 .2 c3 <br /> 317 CCR 2636 , 2643(c)(1 ), Line leak detector (LLD) not installed ❑ V ❑ R ❑ COS <br /> 2666(f) <br /> 318 CCR 2666(c), 2643(c) Leak detector failed to detect a 3 .0 gallons per hour leak at 10 pounds per square inch ❑ V ❑ R ❑ COS <br /> (1 ) <br /> 319 CCR 26353 2637 . 1 , No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be tested ❑ V ❑ R ❑ COS <br /> 2665, 2712 <br /> 320 CCR 2635 , 2637.2 , Failure to comply with the installation , inspection , or record keeping of the overfill prevention ❑ V ❑ R ❑ COS <br /> 2665, 2712 <br /> 321 CCR 2635(c)(1 ) Overfill prevention was overridden ❑ V ❑ R ❑ COS <br /> 322 HSC 25281 .6(a) Unburied below grade emergency generator system failed to meet exemption status ❑ V ❑ R ❑ COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑ V ❑ R ❑ COS <br /> 324 CCR 2717A (g) Tampered with red tag ❑ V ❑ R ❑ COS <br /> 325 CCR 2717 . 1 (f), Deposited or allowed deposit of petroleum or a hazardous substance into a red tagged UST ❑ V ❑ R ❑ COS <br /> 25292.3(c) <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑ V ❑ R ❑ COS <br /> 327 CCR 2631 . 1 , 2660(m) UST system not compatible with the substance stored ❑ V ❑ R ❑ COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑ V ❑ R o COS <br /> 329 HSC 25298; CCR 2670 , Failed to comply with all permanent closure requirements ❑ V ❑ R ❑ COS <br /> 2672 <br /> 330 CCR 2636 (f), 2666(c), No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm ❑ V ❑ R ❑ COS <br /> 2666(f) <br /> 331 CCR 2630(d), 2641 (a) Liquid does not flow into the sump in the event of a leak (i .e . , failure to remove test boot). ❑ V ❑ R ❑ COS <br /> 332 CCR 2631 (b&d), Primary and/or secondary containment not constructed in accordance with the established standards ❑ V :3R ❑ COS <br /> 2666(b&e) <br /> 333 CCR 2635 , 2636(b), Failure to comply with the cathodic protection system requirements ❑ V ❑ R ❑ COS <br /> 2662, 2712 <br /> 334 CCR 2666(b)(2) Single-walled pipe not upgraded to double-walled interstitially monitored pipe during repair ❑ V ❑ R ❑ COS <br /> 335 CCR 2630 , 2632, 2643, Equipment or methods used to monitor the UST system are not certified by an independent third-party ❑ V ❑ R ❑ COS <br /> 2644. 1 <br /> 336 HSC 25292.3(c)(1 )(C ) Owner/operator allowed dispensing from a UST that has a red tag affixed to the fill pipe ❑ V ❑ R ❑ COS <br /> Single -Walled Non -Pressurized Piping <br /> 401 CCR 2636(a)(3)1 Suction piping not properly sloped or incorrectly located check valve ❑ V ❑ R ❑ COS <br /> 2641 (b) <br /> 402 CCR 2643(d) Failure to conduct monitoring / maintain records for single-walled conventional suction (pre-1984) ❑ V ❑ R ❑ COS <br /> 403 CCR 2643(d), 2661 (f) Failure to conduct 0 . 1 gph test for single-walled conventional suction systems (pre-Jan 1984) ❑ V ❑ R ❑ COS <br /> 404 CCR 2643(e), 2661 (f) 0 . 1 -gph line test for single-walled gravity piping not performed biennialy or post repair (pre-1984) ❑ V ❑ R ❑ COS <br /> FA0000293 PR0231487 SCO01 02/19/2020 <br /> EHD 23-01 Rev. 9/20P2019 Page 3 of 5 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 1 T 209 46&34201 F 209 464-0138 1 www .sjcehd . com <br />