My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ESCALON
>
1329
>
2300 - Underground Storage Tank Program
>
PR0231487
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2020 2:35:39 PM
Creation date
6/11/2020 10:43:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231487
PE
2351
FACILITY_ID
FA0000293
FACILITY_NAME
Pershing Holdings, Inc. DBA Esclon Arco
STREET_NUMBER
1329
STREET_NAME
ESCALON
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22510003
CURRENT_STATUS
01
SITE_LOCATION
1329 Escalon Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J OAQU I N Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : Date : <br /> Pershing Holdings , Inc . DBA Esclon Arco 1329 Escalon Ave , Escalon February 19 , 2020 <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑ V ❑ R ❑ COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 103 HSC 25292 .2 , 25299 .30 Failure to submit and maintain complete and current financial responsibility documents . <br /> OBSERVATION : Financial responsibility documents have not been submitted to the EHD . The most recent <br /> financial responsibility documents in CERS are dated 10/13/2017 . <br /> REGULATION GUIDANCE : Current financial responsibility documents are required to be submitted annually . <br /> CORRECTIVE ACTION : Immediately log into the California Environmental Reporting System (CERS ) at <br /> http ://cers .calepa , ca ,gov/, and upload the required documents . <br /> This is a minor violation . <br /> 113 CCR 2638 (c) , 2638 (d ) Failure to submit " Monitoring System Certification Form" within 30 days of completion of the <br /> test. <br /> OBSERVATION : Annual monitoring system certification , leak detector testing , and spill container testing was <br /> performed on 02/19/2019 and a test report was submitted on 08 /14 /2019 , five months late . <br /> REGULATION GUIDANCE : A copy of the test report must be submitted within 30 days of the tests . <br /> CORRECTIVE ACTION : Take all necessary precautions to ensure testing and submittal of test reports are <br /> performed in a timely manner. <br /> This is a minor violation . <br /> 316 HSC 25290A (c3 ) , 25290 .2 (c3 ) Secondary containment not constructed to prevent water intrusion (after Jul 2003 ) . <br /> OBSERVATION : Water was found in the under dispenser containment ( UDC ) sump , UDC #7/8 . <br /> REGULATION GUIDANCE : Secondary containment shall be constructed to prevent any water intrusion into the <br /> system by precipitation , infiltration , or surface runoff. <br /> CORRECTIVE ACTION : The service technician removed less than halve a gallon of liquid from the UDC #7/8 <br /> sump and returned the sensor to its proper location . Immediately contact a properly licensed , trained , and certified <br /> contractor to address the water intrusion into the UDC # 7/8 sump under permit and inspection by the EHD . <br /> This is a minor violation . <br /> Overall Inspection Comments . <br /> An inspection checklist was provided to the facility operator on the day of inspection . The EHD has written the <br /> complete report on 2/21 /2020 which replaces the initial checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation , and any supporting <br /> paperwork , by March 21 , 2020 . <br /> FA0000293 PR0231487 SCO01 02/19/2020 <br /> EHD 23-01 Rev. 9/20/2019 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 T 209 468-3420 F 209 464 -0138 1 www . sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.