Laserfiche WebLink
SAN J OAQU I N Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : Date : <br /> Pershing Holdings , Inc . DBA Esclon Arco 1329 Escalon Ave , Escalon February 19 , 2020 <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑ V ❑ R ❑ COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 103 HSC 25292 .2 , 25299 .30 Failure to submit and maintain complete and current financial responsibility documents . <br /> OBSERVATION : Financial responsibility documents have not been submitted to the EHD . The most recent <br /> financial responsibility documents in CERS are dated 10/13/2017 . <br /> REGULATION GUIDANCE : Current financial responsibility documents are required to be submitted annually . <br /> CORRECTIVE ACTION : Immediately log into the California Environmental Reporting System (CERS ) at <br /> http ://cers .calepa , ca ,gov/, and upload the required documents . <br /> This is a minor violation . <br /> 113 CCR 2638 (c) , 2638 (d ) Failure to submit " Monitoring System Certification Form" within 30 days of completion of the <br /> test. <br /> OBSERVATION : Annual monitoring system certification , leak detector testing , and spill container testing was <br /> performed on 02/19/2019 and a test report was submitted on 08 /14 /2019 , five months late . <br /> REGULATION GUIDANCE : A copy of the test report must be submitted within 30 days of the tests . <br /> CORRECTIVE ACTION : Take all necessary precautions to ensure testing and submittal of test reports are <br /> performed in a timely manner. <br /> This is a minor violation . <br /> 316 HSC 25290A (c3 ) , 25290 .2 (c3 ) Secondary containment not constructed to prevent water intrusion (after Jul 2003 ) . <br /> OBSERVATION : Water was found in the under dispenser containment ( UDC ) sump , UDC #7/8 . <br /> REGULATION GUIDANCE : Secondary containment shall be constructed to prevent any water intrusion into the <br /> system by precipitation , infiltration , or surface runoff. <br /> CORRECTIVE ACTION : The service technician removed less than halve a gallon of liquid from the UDC #7/8 <br /> sump and returned the sensor to its proper location . Immediately contact a properly licensed , trained , and certified <br /> contractor to address the water intrusion into the UDC # 7/8 sump under permit and inspection by the EHD . <br /> This is a minor violation . <br /> Overall Inspection Comments . <br /> An inspection checklist was provided to the facility operator on the day of inspection . The EHD has written the <br /> complete report on 2/21 /2020 which replaces the initial checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation , and any supporting <br /> paperwork , by March 21 , 2020 . <br /> FA0000293 PR0231487 SCO01 02/19/2020 <br /> EHD 23-01 Rev. 9/20/2019 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 T 209 468-3420 F 209 464 -0138 1 www . sjcehd . com <br />