Laserfiche WebLink
DRAFT Ver. 1-C-doc-4-5-1 0 <br /> Table G-19 General Rule Requirements for Onshore Oil Production Facilities N/A <br /> All aboveground valves and piping associated with transfer operations are inspected periodically and ❑ ❑x <br /> upon a regular schedule. The general condition of flange joints, valve glands and bodies, drip pans, pipe <br /> supports, pumping well polish rod stuffing boxes, bleeder and gauge valves, and other such items are <br /> included in the inspection. See Inspection Log and Schedule in Attachment 3.1 112.9(d)(1)1 <br /> An oil spill contingency plan and written commitment of resources are provided for flowlines and intra- ❑ ❑x <br /> facility gathering lines [See Oil Spill Contingency Plan and Checklist in Attachment 2 and Inspection <br /> Log and Schedule in Attachment 3.1] (§112.9(d)(3)] <br /> or <br /> Appropriate secondary containment and/or diversionary structures or equipment is provided for flowlines ❑ ❑x <br /> and intra-facility gathering lines to prevent a discharge to navigable waters or adjoining shorelines. The <br /> entire secondary containment system, including walls and floor, is capable of containing oil and is <br /> constructed so that any discharge from the pipe, will not escape the containment system before cleanup <br /> occurs. <br /> A flowline/intra-facility gathering line maintenance program to prevent discharges from each flowline has ❑ ❑x <br /> been established at this facility. The maintenance program addresses each of the following: <br /> • Flowlines and intra-facility gathering lines and associated valves and equipment are compatible ❑ ❑x <br /> with the type of production fluids, their potential corrosivity, volume, and pressure, and other <br /> conditions expected in the operational environment; <br /> • Flowlines, intra-facility gathering lines and associated appurtenances are visually inspected ❑ ❑x <br /> and/or tested on a periodic and regular schedule for leaks, oil discharges, corrosion, or other <br /> conditions that could lead to a discharge as described in §112.1(b). The frequency and type of <br /> testing allows for the implementation of a contingency plan as described under part 109 of this <br /> chapter. <br /> • Corrective action and repairs to any flowlines and intra-facility gathering lines and associated ❑ ❑x <br /> appurtenances as indicated by regularly scheduled visual inspections, tests, or evidence of a <br /> discharge. <br /> • Accumulations of oil discharges associated with flowlines, intra-facility gathering lines, and ❑ ❑x <br /> associated appurtenances are promptly removed. 112.9(d)(4)1 <br /> The following is a description of the flowline/intra-facility gathering line maintenance program implemented at this <br /> facility: <br /> NEED TO ADD SECTION ITEMS FOR 112.9(c)(6)(i - v) and 112.9(d)(2) and (5). <br /> CALIFORNIA FREIGHT ACAMPO <br /> Facility Name: Page 18 Tier I I Qualified Facility SPCC Plan <br />