Laserfiche WebLink
$©F; <br /> CLEARWAri ER <br /> G R O U P, I I'N C. - <br /> purging activities to insure that the sample is representative of the aquifer.: <br /> Purging will continue until at least three well casing volumes have been <br /> removed, 'the physical parameters stabilize, or until the -well .completely._ . <br /> dewaters. Stability is defined`as a'change of less than 0.2 pH units, less than : <br /> : 10% in micro mhos, and less than 1.0 degree Centigrade. . Wells which <br /> dewater or demonstrate.a slow,recharge, may be sampled after fewer than <br /> three well volumes have been removed.' Well purging: orm <br /> infation will be <br /> recorded on a purge data sheet:. All meters will .be calibrated daily. Purge <br /> water will.be stored 'on.site in D:O.T:-approved 55 gallon :drums, sealed .and <br /> labeled. ..The water .will be removed,to an appropriate disposal 'facility by a.- <br /> licensed <br /> .:licensed hauler. <br /> Ground water samples will be collected immediately. after purging or when <br /> the well has recharged to at least 70% of its static water level. Samples will be <br /> . . ; collected using polyethylene bailers, either disposable-or dedicated to the well. <br /> Samples .for analytes most sensitive to volatilization .will be collected -first. <br /> Water samples will be placed} in theappropriate container. for that analysis, <br /> labeled, documented on a chain of custody forst and..placed on ice in a cooler <br /> for transport to a state-approved analytical laboratory. To prevent <br /> contamination of the samples, CGI personnel will adhere to the following <br /> procedures in the field:. <br /> i� • A new, clean pair of latex gloves will be used for each well to be sampled. <br /> _ Groundwater samples will Abe collected in the expected order of increasing <br /> degree of contamination. <br /> When collecting samples for volatile organic analysis, CGI personnel. will <br /> minimize the amount of Fair passing through the sample. This helps <br /> - _ prevent the air from stripping the volatiles from the water. . Sample <br /> bottles should be filled by slowly running the sample down the side of the <br /> bottle until there is a convex meniscus over the mouth of the bottle. The <br /> lid is then carefully screwed onto the bottle such that no air bubbles are . <br /> present within the bottle. -�`If a bubble. is present, the cap is removed..and <br /> additional water is added' to the sample container. After resealing the <br /> sample container,'if bubbles still are present inside, the sample container is <br /> discarded and the procedure is repeated. <br /> 5 <br /> CLEARWATER GROUP,INC. 4 April 28, 1995 <br /> 4 ` <br />