O: Corrosion Control <br /> Prepared by:JZ61 <br /> MATCOR ANODES 0-13.5 <br /> Asset Type: Gas Transmission and Distribution Function: Construction <br /> Issued by: K. M. Armato � !l�Original Signed_By ? Date: 10-09-08 <br /> Rev.#04: This document replaces Revision #03. For a description of the changes, see Page 4. <br /> Purpose and Scope <br /> This gas numbered document provides installation procedures and ordering information for Matcor anodes. It also <br /> contains an illustration of a Matcor anode. <br /> Acronyms <br /> Amp(s): ampere(s) <br /> AWG: American wire gauge <br /> CPA: cathodic protection area <br /> ETS: electrolysis test station <br /> PVC: polyvinyl chloride <br /> USA: Underground Service Alert <br /> References Document <br /> Plastic Valve Box for 3Z4" -4"Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . ... . . . . . . . . . . . . K-40 <br /> Concrete Valve Box - Street Installation on 2"to 4" Gas Mains incl. . . . . . . . . . . . . . . ... . . . . . . K-41 <br /> Typical Installation of Traffic Valve Box on 2"to 4° Gas Mains Incl . . . . . . . . . . .. . . . . . . . . . . . . . K-41.1 <br /> Non-Concrete Valve Box for 3/4" - 4"Valves Anodes and ETSs . . . . . . .. . . . . .. .. .. . . . . . . . . K-44 <br /> General Information <br /> 1. Available system outputs: 5, 10, and 30 Amps <br /> 2. System design life: 20 years+ at 5, 10, and 30 Amps continuously <br /> 3. For special design considerations contact corrosion engineering personnel. <br /> 4. Matcor anodes are ultra-high efficiency, platinum anodes. <br /> 5. Gross weight: <br /> System: 305 pounds <br /> Backfill: 1,750 pounds <br /> Installation Procedures <br /> The contractor or person drilling a cathodic protection well deeper than 50' must possess a valid C-57 Water Well <br /> Contractor's License (see Section 13750.5 of the California Water Code). The contractor or driller is responsible to <br /> ensure that the following actions are taken: <br /> 1. Perform all work in accordance with the Department of Water Resources Bulletin, "Water Wells and Cathodic <br /> Protection Wells" (Sections 13700 through 13806 of the California Water Code) and the local government agency <br /> requirements. <br /> 2. Ensure that the local office has obtained the proper permits for drilling each deep well from the government <br /> agency with the applicable jurisdiction. Consult with the city, county, and regional water quality control boards <br /> before drilling. Keep the copies of all associated permits on site. Notify USA or verify that USA has been notified <br /> before starting the work. <br /> 3. Drill an 8"diameter hole to the required depth. <br /> 4. Follow the installation instructions found in the system crate. <br /> Rev. #04: 10-09-08 0-13.5 Page 1 of 4 <br />