Laserfiche WebLink
1. FACILITY INFORMATION <br />CERS ID <br />Date of Overfill Prevention Equipment Inspect ion <br />10112f2018 <br />Business Name (Same as Facility !Name or DBA -Doing Business As.) <br />CHEVRON <br />Business Site Address <br />City <br />ZlF' Code <br />6633 PACIFIC AVENUE <br />STOCKTON <br />95207 <br />IL UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br />Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br />GREG KAISER 209 887 - 2639 Ext. <br />Contractorfrank Tester License # ICC Certification # ICC Certification Expiration Date <br />859535 <br />5252318 411112019 <br />Overfill Prevention Equipment inspection Training and Certifications (List applicable certifications.) <br />Ill. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br />Inspection Method Used: 0 Manufacturer Guidelines (Specify) <br />❑ Industry Code or Engineering Standard (Specify) <br />❑ Engineered Method (Specify) <br />Attach the inspection procedures and all documentation <br />required to determine <br />the results. # of Attached Pages: 9 <br />Tank ID: (By tank number, stored product etc.) <br />T1 Super <br />T2 Regular 1 T3 Re alar 2 <br />What is the tank inside diameter? (inches) <br />90.88 <br />90.88 90.88 <br />Is the fill piping secondarily contained? <br />CxI Yes ❑ No <br />0 Yes ❑ No 9 Yes ❑ No ❑ Yes ❑ No <br />Is the vent piping secondarily contained? <br />D Yes ❑ No <br />0 Yes ❑ No 0 Yes [I No ❑ Yes ❑ No <br />Overfill Prevention Equipment Manufacturer(s) <br />Auto Limiter It <br />Auto Limiter 11 Auto Limiter II <br />What is the overfill prevention equipment <br />❑x Shuts Off Flow <br />0 Shuts Off Flow <br />0 Shuts Off Flow Q Shuts Off Flow <br />response when activated? <br />(check all that apply.), <br />❑ Restricts Flow <br />❑ Restricts Flow <br />❑ Restricts Flow ❑ Restficts Flow <br />❑ AN Alarm <br />❑ AIV Alarm <br />❑ AN Alarm ❑ AIV Alarm <br />Are flow restrictors installed on vent piping? <br />❑ Yes 0 No <br />❑ Yes D No <br />El Yes 9 No ❑ Yes ❑ No. <br />At what level in the tank is the overfill prevention <br />set to activate? (inches from bottom of tank.) <br />$1 �'$ <br />81 314 <br />81 114 <br />What is the percent capacity of the tank at which <br />the overfill prevention equipment activates? 94.4% 94.5% <br />94% <br />Is the overfill prevention in proper operating 19 Yes IN Yes <br />0 Yes ❑ Yes <br />condition to respond when the substance ❑ No ❑ No <br />reaches the appropriate level? <br />© No ❑ No <br />(Specify in section V.} (Specify in section V.) <br />(Specify in section V.) (Specify in section V:) <br />IV. SUMMARY OF INSPECTION RESULTS <br />Overfill Prevention Inspection Results(] Pass El Fail 0 Pass ❑Fail <br />(� pass ©Fail ❑ pass OF 71 <br />V. %.Vn nt:N I U <br />All items marked "Fail- must be explained in this section. Any additional comments may also be provided here. <br />Vl. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br />I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations, title 23, division 3, <br />' <br />chapter 16, section 2637.2 an all the inform on contained herein is accurate. <br />UST Service Techni Sin lirn <br />if the facilit has 0 <br />Y ponents than this form accommodates, additional copies of oris page may be attached. <br />CERS = California En ' rita Iting SYS IC = ntifi�tion, UST = Underground stot8ge tank, ICC = Intematbrial Code Counal. AN=Audble and visuai <br />