Laserfiche WebLink
t26 October 2000 <br /> AGE-NC Project No. 98-0466 <br /> ' Page 5 of 10 <br /> 2.1.1. Soil Sample Collection <br /> Discrete soil samples were collected from the probe borings at 5-foot in ervals,beginning at 5 feet <br /> bsg, to total depth of each boring. Soil samples were collected using i Geoprobe soil sampling <br /> assembly loaded with four pre-cleaned 1.125-inch by 6-inch brass sl eves. Soil samples were <br /> preserved by covering both ends of the brass sleeve with Teflon sheets, capping, and sealing with <br /> tape.Each sample sleeve was labeled with soil probe boring location,depth,time,date and sampler's <br /> initials. <br /> ' Soil samples from hand auger borings DSI through DS4 were colle ted utilizing a 2.25-inch <br /> diameter metric soil sampler loaded with one 2-inch by 6-inch brass slee�e. The sampling assembly <br /> was advanced using a slide hammer. Soil samples were preserved by covering both ends of the brass <br /> sleeve with Teflon sheets,capping,and sealing with tape.Each sample sleeve was labeled with soil <br /> probe boring location, depth, time, date and sampler's initials. <br /> ' Each preserved sample was logged on a chain-of-custody form, placedin a chilled container and <br /> transported to Precision Enviro-Tech Analytical Laboratory(PET)a California Department ofHealth <br /> Services (DHS)-certified laboratory under chain of custody; selected samples were analyzed for: <br /> ' • Total recoverable petroleum hydrocarbons(TRPH)in accordance with EPA Method 418.1; <br /> ' • Total petroleum hydrocarbons quantified as diesel(TPH-d)and tot 1 petroleum hydrocarbons <br /> quantified as motor oil (TPH-mo) EPA Method 8015 Modified; <br /> ' • Volatile organic compounds (VOCs) in accordance with EPA Method 8260B; <br /> • Semivolatile organic compounds (SVOCs)PCP and TCP in accordance with EPA Method <br /> 8270; <br /> • Chromium, lead, zinc in accordance with EPA Method 6010; and <br /> • Formaldehyde in accordance with EPA Method 8315. <br /> ' 2.1.2 . Ground Water Sample Collection <br /> One grab ground water sample was collected from LP4 using a tempo ary 1-inch diameter PVC <br /> screen.The probe rods were advanced to total depth,the hollow steel rod were then pulled out,and <br /> the screened casing was inserted into the saturated zone. Ground watei was allowed to enter the <br /> casing, and samples were retrieved using a modified PVC tubing bail er. Sufficient sample was <br /> collected from boring LP4 to fill four 40-m1 EPA-approved VOA via s containing 0.5 ml 18% <br /> hydrochloric acid as a sample preservative and into one 1-liter and one 500-ml amber bottles without <br /> sample preservative. Ground water sample containers were labeled with probe boring designation, <br /> Advanced GmEnvironmental,Inc. <br />