Laserfiche WebLink
SWRCB,January 2002 FINAL DRAFT Page_�L of 5 <br /> 7. UNDER-DISPENSER CONTAINMENT UDC TESTING <br /> Does Facility have UDC(s)? ®Yes❑No <br /> Test Method Developed By: ❑UDC Manufacturer ® Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑ Vacuum ®Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Caldwell Sump Level Change Indicator Equipment Resolution: 0.0025" <br /> UDC# UDC# UDC# UDC# <br /> UNLEADED #1 UNLEADED #2 DIESEL #3 <br /> UDC Manufacturer: Bravo Bravo Bravo <br /> UDC Material: Coated Steel Coated Steel Coated Steel <br /> UDC Depth: 8.00". 7.50" 8.50" <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: 0.00" 0.00" 0.00" <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: 0.00" 0.00" 0.00" <br /> Condition of UDC prior to <br /> testing: Cle Clean/Dry Clean/Dry <br /> Depth of UDC Tested: 5.50" 5.50" 5.75" <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes❑No ®NA Dyes❑No®NA ❑Yes❑No®NA Dyes❑No DNA <br /> product and water)?* <br /> Turbine shutdown response time: Float with Chain Float with Chain Float with Chain <br /> Is system programmed for fail- No® ®NA ❑Yes❑No DNA <br /> safe shutdown? ❑Yes❑No®NA ❑Yes❑ NA ❑Yes❑No <br /> Was fail-safe verified to be ®NA ❑Yes❑No®NA ❑Yes❑No DNA <br /> o erational? ❑Yes❑No RNA ❑Yes❑No <br /> Wait time between applying <br /> pressure/vacuum/water and 5 minutes 5 minutes 5 minutes <br /> starting test: <br /> Test Start Time: 10:05am 10:41am 11:19am <br /> Initial Reading(RI): 5.50" 5.50" 5.75" <br /> Test End Time: 10:37am 11:13am 11:54am <br /> Final Reading(RF): 5.50" 5.50" 5.75" <br /> Test Duration: 32 minutes 32 minutes 35 minutes <br /> Change in Reading(RF-R): 0.00" 0.00" 0.00" <br /> Pass/Fail Threshold or Criteria: 0.00" 0.00" 0.00" <br /> Test Result Pass DFaiI NPass oFail Pass UFail MPass OF0 <br /> Was sensor removed or disabled EYcs[:]No®NA ®Yes❑No®NA ®Yes[]No®NA Dyes❑No DNA <br /> for testing? <br /> Was sensor properly replaced and [Ryes❑No®NA ®Yes❑No®NA ®Yes❑No®NA ❑Yes❑No DNA <br /> verified functional after testin ? <br /> Comments—(Include information on repairs made prior to testing,and recommended follow-up for failed tests.) <br /> UDC's are monitored by FFS DC-400 stand alone sensors. <br /> ' If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO",then the entire UDC should be tested. (See SWRCB LG-160) <br />