My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 12:54:47 PM
Creation date
6/18/2020 1:46:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
115
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REGFIXIED <br /> r <br /> 9 2029 <br /> SWRCB,January 2002 FINAL DRAFT Page 4 of 4 <br /> 6. PIPING SUMP TESTINNVIRQUMENTAL, <br /> Test Method Developed By: ❑ Sump Manufacturer ® Industry Staudad'a,+A nTQ"essional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑ Vacuum ®Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Caldwell Sump Level Change Indicator Equipment Resolution: 0.0025' <br /> Sump# Sump# Sump# Sump# <br /> DIESEL <br /> Sump Diameter: 36.0" <br /> Sump Depth from Top of Tank: 36.0" <br /> Sump Material: FRP <br /> Height from Tank Top to Top of 17.75" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Top of 15.5" <br /> Lowest Electrical Penetration: <br /> Condition of sump prior to testing: Clean/Dry <br /> Depth of Sump Tested' 20.25' <br /> Does turbine shut down when <br /> sump sensor detects liquid(both Dyes❑No®NA ❑Yes❑No[:]NA ❑Yes[:]No DNA ❑Yes❑No❑NA <br /> product and water)?` <br /> Turbine shutdown response time: Suction System <br /> Is system programmed for fail-safe <br /> shutdown?* ❑Yes❑No ®NA [:]Yes❑No DNA ❑Yes[-]No DNA ❑Yes[]No DNA <br /> Was fail-safe verified to be ❑Yes[:]No®NA Dyes❑No DNA ❑Yes❑No DNA ❑Yes❑No❑NA <br /> operational? <br /> Wait time between applying <br /> pressure/vacuum/water and starting 10 minutes <br /> test: <br /> Test Start Time: 2:20p <br /> Initial Reading(RI): 20.25' <br /> Test End Time: 3:07p <br /> Final Reading(RF): 20.25' <br /> Test Duration: 47 minutes <br /> Change in Reading(RF-RO: 0.00" <br /> Pass/Fail Threshold or Criteria: 0.igh <br /> Test Result ®Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail <br /> Was sensor removed for testing? ®Yes❑No❑NA ❑Yes❑No DNA ❑Yes❑No DNA ❑Yes[:]No[:INA <br /> Was sensor properly replaced and <br /> verified functional after testing? ®Yes❑No ❑NA ❑Yes❑No[—INA ❑Yes❑No DNA ❑Yes❑No❑NA <br /> Comments—(Include information on repairs made prior to testing,and recommended follow-up for failed tests.) <br /> Test water is reused,controlled and disposed of by LLNL. <br /> 4 <br /> ' If the entire depth of the sump is not tested,specify how much was tested. If the answer to gpy of the questions indicated with an <br /> asterisk(*)is"NO",then the entire sump should be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.