Laserfiche WebLink
SA NUJ OAHU I N Environmental Health Department <br /> ■ COUNT Y-- <br /> c/l" Greorness grows hey,. Time In:�50pm <br /> Time Out: 1:35 om <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: MEADOWGREEN APARTMENTS Date: 06/16/2020 <br /> Address: 211 W SAN CARLOS WAY, STOCKTON 95207 <br /> Owner/Operator: GOLDEN OPPORTUNITY INVESTMENTS LP Telephone: (626)575-3070 <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #12 pH Level MAJOR <br /> OBSERVATIONS:pH level is over 8.0. If pool reopens this season a re-inspection is required. pH shall be between 7.2-7.8. <br /> CALCODE DESCRIPTION:Pool operator shall maintain pH between 7.2 and 7.8. (CCR 65530) <br /> #2 Pool Enclosure <br /> OBSERVATIONS:Fence metal bar is missing and area is currently covered with wood. Metal bar shall be immediately <br /> re-installed. <br /> CALCODE DESCRIPTION:Pool area shall be enclosed by one or more of the following:a fence,portion of a building, wall, or other <br /> approved durable enclosure.Pool enclosure shall be constructed over a hard permanent material equivalent to concrete and shall be <br /> installed no more than 2 inches above the finished grade. Holes,gaps,or openings in the enclosure shall not allow the passage of a <br /> 4-inch diameter sphere.Doors, openable windows,or gates of living quarters shall not be permitted as part of the pool enclosure. (CBC <br /> 31198) Pool operator shall keep the pool enclosure well maintained. (CCR 65535) Pool enclosure shall have a minimum effective <br /> perpendicular height of 5 feet and shall be constructed so that it cannot be climbed by small children.Horizontal members shall be spaced <br /> at least 48 inches apart. No planters or other climbable structures shall be permitted within 5 feet of the pool enclosure or within a 5-foot <br /> arc. Chain link openings shall not be larger than 1314 inches when measured horizontally. Pool enclosures with a height of 4 or more feet <br /> are allowed if the enclosure was constructed prior to July 1994. (CBC 31198) <br /> #3 Safety Signs <br /> OBSERVATIONS:The following shall be rewritten on safety signs: Pool hours, pool capacity, site address, and phone <br /> number of nearest hospital. Correct by 2 days. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained. (CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole,gate, or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 31206) <br /> #4 Safety Equipment <br /> OBSERVATIONS:Life ring lacks rope. Provide a rope. Length shall be pools width. <br /> CALCODE DESCRIPTION:Safety equipment shall be provided, maintained,readily visible,and available for use.Pools shall have at <br /> minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br /> rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br /> (CCR 65540) <br /> FA0001428 PR0360084 SCO01 06/16/2020 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />