Laserfiche WebLink
S ` ` , J O A Q U I N =nvironmental Health Department <br /> C0U "ATY <br /> Swimming Pool Official Inspection Report <br /> Facility Name and Address: MEADOWGREEN APARTMENTS, 211 W SAN CARLOS WAY, STOCKTON 95207 <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:Pool light is not working. Replace by 1 week.This is a repeat violation. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (31158) <br /> #15 Operation Records <br /> OBSERVATIONS:Did not see pH and chlorine readings in pump room. They shall be available. Start recording readings, <br /> today. <br /> CALCODE DESCRIPTION:Pool operator shall test the disinfectant residual,pH, and spa water temperature a minimum of once per day. <br /> Cyanuric acid concentration shall be tested once per month if cyanuric acid is used. Combined chlorine shall be tested as often as <br /> necessary to maintain the concentration below 0.4 ppm. Pool operator shall maintain written records of all maintenance and test results <br /> for at least two years and shall submit those records to the enforcement agency upon request. (CCR 65523) <br /> #18 Pool Shell and Tile <br /> OBSERVATIONS:Pool lacks several ceramic tiles.Algae is growing in this area were the tiles fell off. Tiles shall be <br /> immediately replaced.This is a repeat violation. <br /> CALCODE DESCRIPTION:Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br /> and scrubbing.A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 31086) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:Skimmers lack weir doors. Provide by 1 week. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31368) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 40 gpm Chlorine: 3.8 ppm Temp: ° F <br /> Cyanuric acid: 90 ppm pH: over 8 Combined chlorine: 0.4 ppm <br /> NOTES <br /> Influent 11 <br /> Effluent 2 <br /> Property manager stated that they are going to keep pool closed this season due to COVID-19. If pool re-opens this season, <br /> call dept for re-inspection before it re-opens.All violations shall be corrected at time of re-inspection. <br /> FA0001428 PR0360084 SCO01 06/16/2020 <br /> EHD 36-01 Rev.06/30/15 Page 2 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />