My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_COMPLIANCE INFO 2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DELAWARE
>
2429
>
3600 - Recreational Health Program
>
PR0360432
>
COMPLIANCE INFO_COMPLIANCE INFO 2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/18/2020 2:31:20 PM
Creation date
6/18/2020 2:30:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
COMPLIANCE INFO 2020
RECORD_ID
PR0360432
PE
3611
FACILITY_ID
FA0001548
FACILITY_NAME
PINE TREE APARTMENTS
STREET_NUMBER
2429
STREET_NAME
DELAWARE
STREET_TYPE
AVE
City
STOCKTON
Zip
95204
APN
12302017
CURRENT_STATUS
01
SITE_LOCATION
2429 DELAWARE AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SA NUJ OAHU I N Environmental Health Department <br /> L■ COUNTY <br /> ^ r1 `p' Greorness grows here, Time In: 9.30 am <br /> Time Out: 10:20 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: PINE TREE APARTMENTS Date: 06/16/2020 <br /> Address: 2429 DELAWARE AVE, STOCKTON 95204 <br /> Owner/Operator: GROUP XIII PROPERTIES LP Telephone: (909)232-6361 <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit Reinspection on or after: 06/19/2020 <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #10 Disinfectant Residual MAJOR <br /> OBSERVATIONS:Free chlorine level is zero. Level shall be maintained between 2.0-10.0 ppm. Correct, immediately. <br /> CALCODE DESCRIPTION:Public pools, when open or in use,shall be disinfected continuously by approved chemicals and shall maintain <br /> the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br /> or 2.0 ppm bromine. Spas, wading pools,and spray grounds shall maintain the following concentrations:3.0 ppm to 10.0 ppm free <br /> chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #16 Water Clarity MAJOR <br /> OBSERVATIONS:Water is green. Main drain cover is not visible.Water shall be clear and main drain visible by 2 days. <br /> CALCODE DESCRIPTION:Pool operator shall maintain clear pool water while pool is in use or shall close the pool if the bottom of the <br /> pool at the maximum depth is not clearly visible from the deck. (CCR 65527) <br /> #3 Safety Signs <br /> OBSERVATIONS:The following shall be written on signs: Pool capacity, pool hours, phone number of nearest hospital and <br /> site address. Correct before re-inspection. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained. (CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole,gate, or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 31206) <br /> #7 Pool Deck <br /> OBSERVATIONS:Deck has large gaps between several concrete slabs (seal came off). Seal before re-inspection. <br /> CALCODE DESCRIPTION:An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br /> top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br /> diving board,ADA device, or slide. (CBC 31148)Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> FA0001548 PR0360432 SCO01 06/16/2020 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.