My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_COMPLIANCE INFO 2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DELAWARE
>
2429
>
3600 - Recreational Health Program
>
PR0360432
>
COMPLIANCE INFO_COMPLIANCE INFO 2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/18/2020 2:31:20 PM
Creation date
6/18/2020 2:30:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
COMPLIANCE INFO 2020
RECORD_ID
PR0360432
PE
3611
FACILITY_ID
FA0001548
FACILITY_NAME
PINE TREE APARTMENTS
STREET_NUMBER
2429
STREET_NAME
DELAWARE
STREET_TYPE
AVE
City
STOCKTON
Zip
95204
APN
12302017
CURRENT_STATUS
01
SITE_LOCATION
2429 DELAWARE AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S ` ` , J O A Q U I N Environmental Health Department <br /> C0U "ATY <br /> Swimming Pool Official Inspection Report <br /> Facility Name and Address: PINE TREE APARTMENTS, 2429 DELAWARE AVE, STOCKTON 95204 <br /> #14 Chemical Water Test Kit <br /> OBSERVATIONS:A D-P-D test kit shall always be available. <br /> CALCODE DESCRIPTION:Pool operator shall maintain a test kit for measuring the disinfectant residual, combined chlorine,pH,and <br /> cyanuric acid(if used)at the pool. Test kit shall be available at all times the pool is in use. Chlorine and bromine test kits shall be DPD <br /> type. Chlorine test kits shall be capable of testing for free and total chlorine,so that combined chlorine concentrations can be determined. <br /> (CCR 65529) <br /> #15 Operation Records <br /> OBSERVATIONS:Start to record pH and free chlorine readings. Have readings on site. <br /> CALCODE DESCRIPTION:Pool operator shall test the disinfectant residual,pH, and spa water temperature a minimum of once per day. <br /> Cyanuric acid concentration shall be tested once per month if cyanuric acid is used. Combined chlorine shall be tested as often as <br /> necessary to maintain the concentration below 0.4 ppm. Pool operator shall maintain written records of all maintenance and test results <br /> for at least two years and shall submit those records to the enforcement agency upon request. (CCR 65523) <br /> #18 Pool Shell and Tile <br /> OBSERVATIONS:Last year plaster was pitted. Pool shall be remodeled soon. Contact this dept and obtain permit for <br /> remodel. <br /> CALCODE DESCRIPTION:Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br /> and scrubbing.A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 31086) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:Skimmer is packed with debris. Basket shall be cleaned. Make sure baskets are not damaged. <br /> Skimmers shall have weir doors and float assemblies. Correct by re-inspection day. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31368) <br /> #27 Pool Equipment Room <br /> OBSERVATIONS:Pump room is dirty and there is clutter. It shall be cleaned and de-cluttered by re-inspection day. <br /> CALCODE DESCRIPTION:Pool operator shall keep ancillary facilities well maintained. (CCR 65535)All filters, valves,pumps,strainers <br /> and equipment shall be readily accessible for repair and replacement. (CBC 31238) <br /> #38 Filter Cleaning and Maintenance <br /> OBSERVATIONS:Filter is not clean. Clean and keep pressure under 10 psi. <br /> CALCODE DESCRIPTION:All filters shall be maintained in accordance with manufacturer's specifications. (CBC 31238)Pressure gauge <br /> located on the filter shall be marked with the clean startup reading. (CBC 31258)Each filter vessel shall be provided with valves so that it <br /> can be isolated from the recirculation system for repairs and backwashing. (CBC 31288) <br /> FA0001548 PR0360432 SCO01 06/16/2020 <br /> EHD 36-01 Rev.06/30/15 Page 2 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.