My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PESCADERO
>
1535
>
2300 - Underground Storage Tank Program
>
PR0232495
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2021 9:54:31 AM
Creation date
6/23/2020 1:57:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0232495
PE
2361
FACILITY_ID
FA0003854
FACILITY_NAME
YRC INC
STREET_NUMBER
1535
Direction
E
STREET_NAME
PESCADERO
STREET_TYPE
Ave
City
Tracy
Zip
95304
APN
21306046
CURRENT_STATUS
01
SITE_LOCATION
1535 E Pescadero Ave
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> LUUNIY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : Date : <br /> YRC INC 1535 E Pescadero Ave , Tracy February 13 , 2020 <br /> UST System Observations <br /> 313 HSC 25290. 11 25290.21 Failure to construct, operate, and maintain primary containment as product-tight n V ❑ R ❑ COS <br /> 125291 <br /> 314 HSC 25290. 1 , 25290.2, Failed to have secondary containment or secondary containment not tight o V n R o COS <br /> 25291 <br /> 315 HSC 25291 (a) Water in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003) n V ❑ R ❑ COS <br /> 316 HSC 25290. 1 (c3) , Secondary containment not constructed to prevent water intrusion (after Jul 2003) ❑ V ❑ R o COS <br /> 25290.2(c3) <br /> 317 CCR 2636, 2643(c)(1 ), Line leak detector (LLD) not installed n V o R n COS <br /> 2666(f) <br /> 318 CCR 2666(c) , 2643(c) Leak detector failed to detect a 3. 0 gallons per hour leak at 10 pounds per square inch ❑ V ❑ R ❑ COS <br /> (1 ) <br /> 319 CCR 2635, 2637. 1 , No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be tested ■ V o R n COS <br /> 2665, 2712 <br /> 320 CCR 2635, 2637.2, Failure to comply with the installation, inspection , or record keeping of the overfill prevention o V ❑ R ❑ COS <br /> 12665, 2712 <br /> 321 CCR 2635(c) (1 ) Overfill prevention was overridden o V D R o COS <br /> li <br /> 322 HSC 25281 .6(a) Unburied below grade emergency generator system failed to meet exemption status o V o R o COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status o V o R o COS <br /> 324 CCR 2717. 1 (g) Tampered with red tag D V o R n COS <br /> 325 CCR 271741 (01Deposited or allowed deposit of petroleum or a hazardous substance into a red tagged UST D V o R o COS <br /> 25292. 3(c) <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V D R o COS <br /> 327 CCR 2631 . 1 , 2660(m) UST system not compatible with the substance stored DV o R o COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements o V o R o COS <br /> 329 HSC 25298; CCR 2670, Failed to comply with all permanent closure requirements o V o R n COS <br /> 2672 <br /> 330 CCR 2636(% 2666(c) , No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm n V o R o COS <br /> 2666(f) <br /> 331 CCR 2630(d), 2641 (a) Liquid does not flow into the sump in the event of a leak (i.e. , failure to remove test boot). o V o R o COS <br /> 332 CCR 2631 (b&d)2 Primary and/or secondary containment not constructed in accordance with the established standards o V n R o COS <br /> 2666(b&e) <br /> 333 CCR 2635, 2636(b) , Failure to comply with the cathodic protection system requirements o V ❑ R D COS <br /> 2662, 2712 <br /> 334 CCR 2666(b)(2) Single-walled pipe not upgraded to double-walled interstitially monitored pipe during repair o V D R o COS <br /> 335 CCR 26300 2632, 2643, Equipment or methods used to monitor the UST system are not certified by an independent third-parry D V o R o COS <br /> 2644. 1 <br /> 336 HSC 25292. 3(c)(1 )(C) Owner/operator allowed dispensing from a UST that has a red tag affixed to the fill pipe o V o R o COS <br /> Single-Walled Non -Pressurized Piping <br /> 401 CCR 2636(a) (3) , Suction piping not properly sloped or incorrectly located check valve ❑ V ❑ R ❑ COS <br /> 2641 (b) <br /> 402 CCR 2643(d) Failure to conduct monitoring / maintain records for single-walled conventional suction (pre-1984) o V o R o COS <br /> 403 <br /> 3CCR 2643(d), 2661 (f) Failure to conduct 0. 1 gph test for single-walled conventional suction systems (pre-Jan 1984) o V o R o COS <br /> 404 CCR 2643(e), 2661 (f) 0. 1 -gph line test for single-walled gravity piping not performed biennialy or post repair (pre-1984) o V o R o COS <br /> FA0003854 PR0232495 SCO01 02/13/2020 <br /> EHD 23-01 Rev, 9/20/2019 Page 3 Of 6 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468-3420 1 F 209 464-0138 1 www. sjcehd. com <br />
The URL can be used to link to this page
Your browser does not support the video tag.