2300 - Underground Storage Tank Program
>
PR0232495
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2021 9:54:31 AM
Creation date
6/23/2020 1:57:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0232495
PE
2361
FACILITY_ID
FA0003854
FACILITY_NAME
YRC INC
STREET_NUMBER
1535
Direction
E
STREET_NAME
PESCADERO
STREET_TYPE
Ave
City
Tracy
Zip
95304
APN
21306046
CURRENT_STATUS
01
SITE_LOCATION
1535 E Pescadero Ave
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> COUNI ,' <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : Date : <br /> YRC INC 1535 E Pescadero Ave, Tracy February 13 , 2020 <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑ V ❑ R ❑ COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1, CLASS II, or MINOR = Notice to Comply) <br /> Item 4 Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> OBSERVATION : UST Tank Information forms are not current in the California Environmental Reporting System <br /> ( CERS ) . <br /> -The plan for the waste diesel tank incorrectly states the riser is fiberglass . <br /> REGULATION GUIDANCE : Any change of information must be updated in CERS within 30 days of the changes . <br /> CORRECTIVE ACTION : Immediately log into CERS , update the required information , and submit for review by the <br /> EHD . <br /> This is a Class II violation . <br /> 105 CCR 2632 (d ) ( 1 ) , 2634(d) Failed to have an approved UST monitoring plan . <br /> OBSERVATION : The monitoring plan is not current and/or not approved by the EHD . <br /> -The plans for the 6 , 000 gallon used oil tank and the gear oil tank incorrectly state the annulars are dry and the <br /> sensor is a 303 . <br /> -The plans for all tanks incorrectly state that the piping sensors are 208 . <br /> -The plans for all tanks left blank the questions regarding leak alarms triggering automatic pump shutdown and <br /> failure/disconnect shutdown blank. <br /> REGULATION GUIDANCE : The monitoring plan must be uploaded to the California Environmental Reporting <br /> System ( CERS) . <br /> i <br /> CORRECTIVE ACTION : Immediately log into CERS , make the necessary changes , and submit for review by the <br /> I EHD . <br /> This is a minor violation . <br /> 204 CCR 2712(1) Current monitoring plan approved by the EHD not found on site . <br /> OBSERVATION : An approved copy of the monitoring plans were not available for inspection . <br /> REGULATION GUIDANCE : A copy of these plans shall be accessible on site at all times . <br /> CORRECTIVE ACTION : Immediately locate and retain a copy on site . <br /> This is a minor violation . <br /> FA0003854 PR0232495 SCO01 02/13/2020 <br /> EHD 23-01 Rev. 9/20/2019 Page 4 of 6 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.